Home > Products > Industrial Supplies > Electrical & Electronic Product Equipment

Three Single phase power controller  1Three Single phase power controller  2Three Single phase power controller  3Three Single phase power controller  4Three Single phase power controller  5
  • Three Single phase power controller  1
  • Three Single phase power controller  2
  • Three Single phase power controller  3
  • Three Single phase power controller  4
  • Three Single phase power controller  5

Three Single phase power controller

Model:TMPT0204L
Brand:TOPTAWA
Origin:Made In Taiwan, China
Category:Industrial Supplies / Electrical & Electronic Product Equipment
Label:TOPTA , Power , regulator
Price: ¥1100 / pc
Min. Order:1 pc
Inquire Now

Member Information

Detail

Shanghai Haabee Electric Co.,Ltd

Free MemberShang Hai - China
Last Online:18 Jul, 2023

Product Description

TOPTAWA is a famous manufacturer, the products cover power controller SCR, SSR, etc. DuoGe field SSC TOPTAWA established to now have 20 years, product good quality, low price, favored by the majority of customers. TOPTAWA in 1990, the company introduced in Japan "TOKIWA" series temperature control products manufacturing technology. Through 10 DuoNian improvement and innovation, and with latest concept of industrial integration technology, make the product more hasten is stable and perfect. TOPTAWA provides 24 hours after sale service. The products using combined design, maintenance and spare part replacement is very convenient, and we will always provide service for you.

 

Product categories:

Three phase power controller (TMPT series, PT series)

Single phase power controller (PS series)

Three-phase zero power controller (ZT series)

Single phase zero power controller (ZS)

Three-phase three extremely, three-phase 2 extremely solid contactor (SSC series)

Three-phase solid power regulator (SRS series)

Solid state relays (SSR series)

TMPT series:

TMPT0204; TMPT0304; TMPT0504; TMPT0704; TMPT1004; TMPT1204; TMPT1604; TMPT2004; TMPT2504; TMPT3004

Rated load current: 20 a. 30 A 50 a.. 70 A. 100 A. 120 A. 160 A. 200 A. 250 A. 300 A

Rated load voltage: 380 V

'inch: (20 a. 30 A 50 A). 98.5 * 126 * 170;

(70 A. 100 A. 120 A) 208 * 140 * 200;

(160 A. 200 A.) 468 * 140 * 200

A. 300 A (250) 648 * 190 * 215

Net weight: 1500 g. 1900 g. 4800 g. 9400 g. 14800 g

Auxiliary power: 88-264 V (50 Hz ac / 60 Hz ac)

The minimum operating current: 0.6 A

When open leakage current: 8 ma (R, C below the Filter)

Energy consumption work rate: 3.2 W (Max)

Use frequency range: 50 Hz ac / 60 Hz ac plus or minus 5%

Control system party type: (4-20 mA DCA, 0 to 20 mA), DCV (0-5 V, 1-5 V, 2-10 V, 0-10 V)

Lose into resistance DCA resistance: 250 (), DCV ohm (4.7 K ohms or 10 K ohms)

Unique margin pressure: AC 2000 V power (1 MIN of I/o)

Police reported by a point: no

 

SSC series

 

Three-phase three very: 3030 h. 3050 h. h. 3100 3070 h.264 h. 3160 h. h. h. 3200 3250 3300 H.

 

Three phase 2 extremely: (2030 h. h. 2072 2050 h.264 h. 2120 h. 2160 h. h. h. 2200 2250 2300 H.

 

Rated load current: 30 a. 50 a. 70 A. 100 A. 120 A. 160 A. 200 A. 250 A. 300 A.

 

Rated load voltage: 380 V

 

Control mode: DC 11-32 V

 

Input impedance: 600 ohms

Size: (three-phase three extremely) 30 A (98.5 * 126 * 170); 50 A (133 * 126 * 170);

70 A. 100 A. 120 A (208 * 140 * 200); 160 A. 200 A (468 * 140 * 200)

250 A. 300 A (648 * 190 * 215)

Size: (three-phase 2 extremely) 30 a. 50 A (98.5 * 126 * 170);

70 A (175 * 126 * 170) 100 A. 120 A (208 * 140 * 200);

160 A. 200 A (350 * 140 * 200); 250 A. 300 A (468 * 140 * 200)

Net weight: (three-phase three extremely) 30 A (1500 g); A (1900 g) 50; 70 A. 100 A. 120 A (4800 g)

160 A. 200 A (9400 g); 250 A. 300 A (14800 g).

(2) A three-phase 30 A 50 a.. (1500 g); 70 A (2400 g); 100 A. 120 A

(4800 g); 160 A. 200 A (7000 g); 250 A. 300 A (9400 g).

The minimum operating current: 0.6 A

When open leakage current: 8 ma (R, C below the Filter)

DC: (three-phase current work three extremely) DCA 10 mA (Min);

(three-phase 2 extremely) 10 mA (Min)

Use frequency range: 50 Hz ac / 60 Hz ac

Insulation voltage: (very) three-phase three AC2000V (1 MIN of I/o)

(three-phase 2 extremely AC2500V) (1 MIN of I/o)

 

Alarm contacts: no

 

Characteristics description:

1, no mechanical switch sparks of problems.

2, no noise free.

3, ON/OFF quickly.

4, product reliability high, long service life.

5, dc control, and AC power supply isolation, wiring easily, without auxiliary power.

 

ZT series: 0204.0304.0504.0704.1004.1204.1604.2004.25043004

Rated load current: 20 a. 30 A 50 a.. 70 A. 100 A. 120 A. 160 A. 200 A. 250 A. 300 A

Rated load voltage: 380 V

Size: (20 A) 98.5 * 126 * 115; (30 A) 98.5 * 126 * 170; (50 A) 133 * 126 * 170; (70 A. 100 A. 120 A) 208 * 140 * 200; A. 200 A (160) 350 * 140 * 200; A. 300 A (250) 468 * 140 * 200

Net weight: 700 g. 1500 g. 1900 g. 4800 g. 7000 g. 9400 g

Auxiliary power: 88-264 V (50 Hz ac / 60 Hz ac)

The minimum operating current: 0.6 A

When open leakage current: 8 Ma (R, C below the Filter)

Power consumption: 3.2 W (Max)

Use frequency range: 50 Hz ac / 60 Hz ac + /-5%

Control mode: DCA (4 to 20 mA, 0 to 20 mA), DCV (0-5 V, 1-5 V, 2-10 V, 0-10 V)

Input impedance: DCA (250 ohms), DCV (4. 7 K ohms or 10 K ohms)

Insulation voltage: AC2000V (1 MIN of I/o)

Alarm contacts: no

 

 

TOPTAWA cycle controller/TOPTAWA power controller/TOPTAWA power regulator

 

Characteristics description:

1, has the power system and the R.S.T) owe phase (abnormal led shows, SCR stop due to the output, produce waves make the fuse is owed a wave burned. R.S.T after recovery, automatic back to normal mode, SCR abnormal lights out, without any reset action, to achieve optimal automation control realm.

2, has the fuse, abnormal led shows, stop the function of SCR output. When the fuse troubleshooting, automatically resume normal work mode.

3, auxiliary voltage range: 88 V AC 264 V AC (50 Hz AC / 60 Hz AC), elastic application range and more suitable for voltage instability of the regional use.

4, system power supply (R.S.T) 50 Hz ac / 60 Hz ac automatic identification, to achieve optimal conditions of perfect power output, suitable for all countries in the world to use.

5, no transmission, save the trouble order distribution working hours, artificial cost, material loss, and can raise work efficiency.

6, any time to start (SCR), all have the function of slow start, reduce the impulse current, can prolong service life of the fuse.

7, small volume, troubleshooting easier.

8, fan to use the patent of extraction, greatly overcome way to maintenance problems.

9, contains maximum output SCR set VR, need not external.

10, otherwise over electric current, over voltage, current, voltage, set for heater disconnection etc function and the corresponding alarm contact output, can follow the user's request design, detailed the content, please contact the company.

 

TOPTAWA power regulator TOPTAWA adjustable power controller dynamometer power regulator power controller TOPTAWA power regulator controlled pressure regulator

 

TOPTAWA electrical heating control experts trustworthy brand !

 

 

Product categories:

Three phase power controller (TMPT series, PT series)

Single phase power controller (PS series)

Three-phase zero power controller (ZT series)

Single phase zero power controller (ZS)

Three-phase three extremely, three-phase 2 extremely solid contactor (SSC series)

Three-phase solid power regulator (SRS series)

Solid state relays (SSR series)

TMPT series:

TMPT0204; TMPT0304; TMPT0504; TMPT0704; TMPT1004; TMPT1204; TMPT1604; TMPT2004; TMPT2504; TMPT3004

Rated load current: 20 a. 30 A 50 a.. 70 A. 100 A. 120 A. 160 A. 200 A. 250 A. 300 A

Rated load voltage: 380 V

'inch: (20 a. 30 A 50 A). 98.5 * 126 * 170;

(70 A. 100 A. 120 A) 208 * 140 * 200;

(160 A. 200 A.) 468 * 140 * 200

A. 300 A (250) 648 * 190 * 215

Net weight: 1500 g. 1900 g. 4800 g. 9400 g. 14800 g

Auxiliary power: 88-264 V (50 Hz ac / 60 Hz ac)

The minimum operating current: 0.6 A

When open leakage current: 8 ma (R, C below the Filter)

Energy consumption work rate: 3.2 W (Max)

Use frequency range: 50 Hz ac / 60 Hz ac plus or minus 5%

Control system party type: (4-20 mA DCA, 0 to 20 mA), DCV (0-5 V, 1-5 V, 2-10 V, 0-10 V)

Lose into resistance DCA resistance: 250 (), DCV ohm (4.7 K ohms or 10 K ohms)

Unique margin pressure: AC 2000 V power (1 MIN of I/o)

Police reported by a point: no

 

SSC series

 

Three-phase three very: 3030 h. 3050 h. h. 3100 3070 h.264 h. 3160 h. h. h. 3200 3250 3300 H.

 

Three phase 2 extremely: (2030 h. h. 2072 2050 h.264 h. 2120 h. 2160 h. h. h. 2200 2250 2300 H.

 

Rated load current: 30 a. 50 a. 70 A. 100 A. 120 A. 160 A. 200 A. 250 A. 300 A.

 

Rated load voltage: 380 V

 

Control mode: DC 11-32 V

 

Input impedance: 600 ohms

Size: (three-phase three extremely) 30 A (98.5 * 126 * 170); 50 A (133 * 126 * 170);

70 A. 100 A. 120 A (208 * 140 * 200); 160 A. 200 A (468 * 140 * 200)

250 A. 300 A (648 * 190 * 215)

Size: (three-phase 2 extremely) 30 a. 50 A (98.5 * 126 * 170);

70 A (175 * 126 * 170) 100 A. 120 A (208 * 140 * 200);

160 A. 200 A (350 * 140 * 200); 250 A. 300 A (468 * 140 * 200)

Net weight: (three-phase three extremely) 30 A (1500 g); A (1900 g) 50; 70 A. 100 A. 120 A (4800 g)

160 A. 200 A (9400 g); 250 A. 300 A (14800 g).

(2) A three-phase 30 A 50 a.. (1500 g); 70 A (2400 g); 100 A. 120 A

(4800 g); 160 A. 200 A (7000 g); 250 A. 300 A (9400 g).

The minimum operating current: 0.6 A

When open leakage current: 8 ma (R, C below the Filter)

DC: (three-phase current work three extremely) DCA 10 mA (Min);

(three-phase 2 extremely) 10 mA (Min)

Use frequency range: 50 Hz ac / 60 Hz ac

Insulation voltage: (very) three-phase three AC2000V (1 MIN of I/o)

(three-phase 2 extremely AC2500V) (1 MIN of I/o)

 

Alarm contacts: no

 

Characteristics description:

1, no mechanical switch sparks of problems.

2, no noise free.

3, ON/OFF quickly.

4, product reliability high, long service life.

5, dc control, and AC power supply isolation, wiring easily, without auxiliary power.

 

ZT series: 0204.0304.0504.0704.1004.1204.1604.2004.25043004

Rated load current: 20 a. 30 A 50 a.. 70 A. 100 A. 120 A. 160 A. 200 A. 250 A. 300 A

Rated load voltage: 380 V

Size: (20 A) 98.5 * 126 * 115; (30 A) 98.5 * 126 * 170; (50 A) 133 * 126 * 170; (70 A. 100 A. 120 A) 208 * 140 * 200; A. 200 A (160) 350 * 140 * 200; A. 300 A (250) 468 * 140 * 200

Net weight: 700 g. 1500 g. 1900 g. 4800 g. 7000 g. 9400 g

Auxiliary power: 88-264 V (50 Hz ac / 60 Hz ac)

The minimum operating current: 0.6 A

When open leakage current: 8 Ma (R, C below the Filter)

Power consumption: 3.2 W (Max)

Use frequency range: 50 Hz ac / 60 Hz ac + /-5%

Control mode: DCA (4 to 20 mA, 0 to 20 mA), DCV (0-5 V, 1-5 V, 2-10 V, 0-10 V)

Input impedance: DCA (250 ohms), DCV (4. 7 K ohms or 10 K ohms)

Insulation voltage: AC2000V (1 MIN of I/o)

Alarm contacts: no

 

 

TOPTAWA cycle controller/TOPTAWA power controller/TOPTAWA power regulator

 

Characteristics description:

1, has the power system and the R.S.T) owe phase (abnormal led shows, SCR stop due to the output, produce waves make the fuse is owed a wave burned. R.S.T after recovery, automatic back to normal mode, SCR abnormal lights out, without any reset action, to achieve optimal automation control realm.

2, has the fuse, abnormal led shows, stop the function of SCR output. When the fuse troubleshooting, automatically resume normal work mode.

3, auxiliary voltage range: 88 V AC 264 V AC (50 Hz AC / 60 Hz AC), elastic application range and more suitable for voltage instability of the regional use.

4, system power supply (R.S.T) 50 Hz ac / 60 Hz ac automatic identification, to achieve optimal conditions of perfect power output, suitable for all countries in the world to use.

5, no transmission, save the trouble order distribution working hours, artificial cost, material loss, and can raise work efficiency.

6, any time to start (SCR), all have the function of slow start, reduce the impulse current, can prolong service life of the fuse.

7, small volume, troubleshooting easier.

8, fan to use the patent of extraction, greatly overcome way to maintenance problems.

9, contains maximum output SCR set VR, need not external.

10, otherwise over electric current, over voltage, current, voltage, set for heater disconnection etc function and the corresponding alarm contact output, can follow the user's request design, detailed the content, please contact the company.

 

TOPTAWA power regulator TOPTAWA adjustable power controller dynamometer power regulator power controller TOPTAWA power regulator controlled pressure regulator

 

TOPTAWA electrical heating control experts trustworthy brand


Product Image

Three Single phase power controller  1
Img 1
Three Single phase power controller  2
Img 2
Three Single phase power controller  3
Img 3
Three Single phase power controller  4
Img 4
Three Single phase power controller  5
Img 5

Send Inquiry to this Member

Shanghai Haabee Electric Co.,Ltd

No. 888, Huanhu West 2nd Road, Pudong New Area, ShanghaiP.R.China(201615)

Phone:
86-21-33734852
Fax:
86-21-37745335
Contact:
WENBAO.FU (Manager)
Mobile:
18930946195

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Electrical & Electronic Product Equipment Made In China Products

,  

Electrical & Electronic Product Equipment China Suppliers and China Manufacturers