2 000 MΩ or more (DC50 V) (between bridge and main body)
Temp. range, compensated
-10 ℃ ~ 50 ℃
Temp. range, safe
-10 ℃ ~ 50 ℃
Temp. effect on zero
0.04 %R.O./10 ℃
Temp. effect on output
0.012 %LOAD/10 ℃
Cable
φ3.2, 4-cores shielded 40 cm cable directly attached. and cable end is separated.
Class of protection
IP64
Material of element
Alluminium alloy
Durability
1 000 000 times with rated load applied.
Effect of eccentric load
- Size of loading plate is 200 mm x 200 mm at maximum.
- The center of loading plate and the center of load cell should be the same position
- Error is within 0.02 %R.O. applied with 1/2 of rated capacity at the position of 50 mm of eccentricity.