Model: | - |
---|---|
Brand: | HOLYKELL |
Origin: | - |
Category: | Electronics & Electricity / Transducer |
Label: | Submersible Pressure , Level Transducers , Transmitters |
Price: |
-
|
Min. Order: | - |
Last Online:15 Nov, 2013 |
Electronic Wire Connections
|
||||||||||||||||||
|
HPT604
|
Submersible Pressure Level Transducers & Transmitters
|
|||||||||
|
Range code
|
Pressure range
|
Ref.
|
Range code
|
Pressure range
|
Ref.
|
||||
01
|
0....0.1 Bar/0-1mH2O
|
G
|
16
|
0....4 Bar / 0-40 mH2O
|
G/A
|
|||||
02
|
0....0.2 Bar/0-2 mH2O
|
G
|
17
|
0....4.5 Bar / 0-45 mH2O
|
G/A
|
|||||
03
|
0....0.3 Bar/0-3 mH2O
|
G
|
18
|
0....5 Bar / 0-50 mH2O
|
G/A
|
|||||
04
|
0....0.4 Bar/0-4 mH2O
|
G
|
19
|
0....5.5 Bar / 0-55 mH2O
|
G/A
|
|||||
05
|
0....0.5 Bar/0-5 mH2O
|
G
|
20
|
0....6 Bar / 0-60 mH2O
|
G/A
|
|||||
06
|
0....0.6 Bar/0-6 mH2O
|
G
|
21
|
0....7 Bar / 0-70 mH2O
|
G/A
|
|||||
07
|
0....0.7 Bar/0-7 mH2O
|
G
|
22
|
0....8 Bar / 0-80 mH2O
|
G/A
|
|||||
08
|
0....0.8 Bar/0-8 mH2O
|
G
|
23
|
0....9 Bar / 0-90 mH2O
|
G/A
|
|||||
09
|
0....0.9 Bar/0-9 mH2O
|
G
|
24
|
0....10 Bar / 0-100 mH2O
|
G/A
|
|||||
10
|
0....1 Bar/0-10 mH2O
|
G/A
|
25
|
0....15 Bar / 0-150 mH2O
|
G/A
|
|||||
11
|
0....1.5 Bar / 0-15 mH2O
|
G/A
|
26
|
0....20 Bar / 0-200 mH2O
|
G/A
|
|||||
12
|
0....2 Bar / 0-20 mH2O
|
G/A
|
27
|
0....30 Bar / 0-300 mH2O
|
G/A
|
|||||
13
|
0....2.5 Bar / 0-25 mH2O
|
G/A
|
28
|
0....40 Bar / 0-400 mH2O
|
G/A
|
|||||
14
|
0....3 Bar / 0-30 mH2O
|
G/A
|
29
|
0....50 Bar / 0-500 mH2O
|
G/A
|
|||||
15
|
0....3.5 Bar / 0-35 mH2O
|
G/A
|
30
|
By Customized
|
G/A
|
|||||
|
Code
|
Pressure type
|
||||||||
G
|
Gauge
|
|||||||||
A
|
Absolute
|
|||||||||
|
Code
|
Power Supply
|
||||||||
S3
|
24 V DC (stabdard)
|
|||||||||
S5
|
12 V DC
|
|||||||||
S6
|
5 V DC
|
|||||||||
S10
|
12~36 V DC
|
|||||||||
|
Code
|
Signal Output
|
||||||||
E0
|
1-5 V (3 wires)
|
|||||||||
E5
|
4-20 mA (2 wires)
|
|||||||||
E6
|
0-5 V (3 wires)
|
|||||||||
E7
|
0-10 V (3 wires)
|
|||||||||
E8
|
0.5-4.5 V (3 wires)
|
|||||||||
E20
|
By Customized
|
|||||||||
|
Code
|
Electronic connection
|
||||||||
C
|
Directly Cable IP68
|
|||||||||
|
Code
|
Accuracy
|
||||||||
1
|
±0.5%F.S
|
|||||||||
2
|
±0.25%F.S
|
|||||||||
3
|
±0.1%F.S
|
|||||||||
HPT604
|
03
|
G
|
S4
|
E5
|
C
|
1
|
Remarks
|
Model:
Parameter:
|
HPT604
|
|||
Characteristic:
|
Various configurations
Corrosive proof, explore proof and leakage proof functions
Highly-efficient lighting protection and strong RFI & EMI resistance
High accuracy and well stability
|
|||
Applications:
|
a. Water tank level measurement and control.
b. Fuel tank level measurement and monitor (diesel, gasoline, kerosene, crude oil and so on).
c. Liquid level measuring in tank, rivers, lake, sea, well, tube, underground container, sewer and so on.
d. Special occasion such as high temperature liquid(up to 100 degree C), strongly corrosion liquid level measurement (request by customized.)
|
|||
Pressure Range:
|
-1 Bar-0-1 Bar…..50 Bar / 0-1M……..500M H2O Optional
|
|||
Overload:
|
150% F.S.
|
|||
Burst Pressure
|
300% F.S.
|
|||
Accuracy:
(Linearity; Hysteresis;
Repeatability)
|
≤ ±0.5%F.S; ≤ ±0.25%F.S; ≤ ±0.1%F.S
Including non-lin., rep. and hys.
Optional
|
|||
Long Stability:
|
Standard: 0.2%F.S±0.05%
|
|||
Working Temp:
|
-30℃~70℃
|
|||
Storage Temp:
|
-40℃~90℃
|
|||
Temperature Compensation:
|
-20℃~65℃
|
|||
Medium compatible:
|
Compatible with 316L Stainless Steel
|
|||
Electronic Wire:
|
2 Wires
|
3 Wires
|
||
Output:
|
4~20mA
|
1~5V / 0~5V
|
0~10 V
|
0.5~4.5 V
|
Power Supply:
|
12~36 V DC
|
10~36 V DC
|
12~36Vdc
|
5 V DC
|
Insulate resistance:
|
>100M Ω@100V
|
|||
Zero Temp. Drift:
|
0.03%FS/℃(≤100kPa); 0.02%FS/℃(>100kPa)
|
|||
FS Temp. Drift:
|
0.03%FS/℃(≤100kPa); 0.02%FS/℃(>100kPa)
|
|||
Electronic connection:
|
Fixed cable and water proof IP68
|
|||
Response time:
|
≤4 ms
|
|||
Pressure Type:
|
Gauge pressure; Absolute pressure optional.
|
|||
Certificate approving:
|
ExdIICT6 and CE Certificate approving (by request)
|
|||
EMC Standard:
|
electromagnetic radiation:EN50081-1/-2
electromagnetic susceptibility:EN50082-2
|
|||
Lighting Protection:
|
Air conduction more than 8000V; external sensor more than 4000 Voltage protection.
|
|||
Cable optional:
|
Cable materials are optional according request, we offer 3 type special cable as follow:
PE Cable(Water Proof); PUR Cable(Oil Proof); PTFE Cable(Anti-Corrosive).
|
|||
Weight:
|
Net weight is about 0.35KG, Full Packing weight is about 0.5KG (Not Include Cable)
|
|||
Remarks:
|
Special applications request by order
|