Model |
HT2000BC-248 |
AC Output |
Rated Power |
2000W |
Output Voltage |
220/230VAC |
Frequency |
50/60Hz±0.1Hz |
Standby Mode |
≤10W |
Output Accuracy |
±3% |
Output Waveform |
Linear load (THD<1%) |
Battery Input |
Battery Voltage |
48V |
Rated Current |
50A |
Voltage Range |
42 ~ 60VDC |
Battery Low Voltage Warning Point |
45V |
Battery Low Voltage Power Off Point |
42V |
Max. Efficiency |
92% |
Bypass Input |
AC Bypass Input Voltage |
220Vac±10% |
AC Bypass Input Frequency |
50/60Hz |
AC Bypass Output Current |
9A |
Switching Time |
≤10ms |
PV Charge Controller |
PV Max. Short Circuit Current |
25A |
PV Max. Open circuit Voltage |
75V |
Max. Charging Current |
25A |
Max. Charging Power |
1200W |
Charging Control Mode |
MPPT |
Max. Efficiency |
98.20% |
AC Charger (optional) |
Max. Charging Voltage |
57V |
Max. Charging Current |
6A |
AC Max. Charging Current |
300W |
Environment |
Anbient Temperature |
0℃~ +40℃ |
Humidity |
≤90%, non-condensing |
Altitude |
2000m |
Protection Function |
Over Temperature Protection Point |
75℃± 5℃ |
Output Short Circuit |
Close Output Voltage and Reset |
Overload Protection |
Over 105-115% load, it will last 3 min; over 115-150%, last 30 sec; >150%, last 10 main electricity supply cycles |
Display |
Displayer |
LCD/LED |
Display Content |
Battery Voltage, Output Load, Operational Mode, Fault Information and Operation Condition |
Size (W×H×D) |
482×88×460 mm |
Weight |
8 Kg |