Bank Interlock Access Control

Bank Interlock Access Control
型号:SW3020E
品牌:SW see-world
原产地:中国
类别:安全、防护 / 门禁考勤器材及系统
标签︰门禁控制器 , 门禁厂家 , 银行门禁
单价: -
最少订量:1 件
发送查询
点击这里给我发消息

产品描述

Interlock Access Control System for Bank
1.What Bank Interlock Access Control System is;
Bank robbery is more and more common in the world.Crimes committed against banks become significant problem. Therefore, how to promote the security of bank becomes very important for a country.Shenzhen zectal electronic co., ltd,our company design the Bank Interlock Access Control System SW3020.
With special voice prompt function and Digital Signal Processing technology,SW3020 is dedicated used in Business hall of bank,and also some prisons.
What Bank Interlock Access Control System is;
There are 2 doors for the Business Hall of banks,Door A and Door B.Any person open the door A,then enter the Business Hall.For the security of the bank,If he try to open the door B,he have to make sure door A is closed completely.
SW3020 control the locking of these 2 doors, such that if one door is open or unlocked, the remaining doors refuse access.Each door is electrically locked and monitored. The control electronics then generates a control signal to indicate when the door is closed and secure. Each controller also has a Door Sensor to detect the door state. By cross connecting these control signals, the door controllers communicate the door status, and only open one door at any given time.
With the special Voice Prompt Function,the machine can remind you in time.Make sure the operator obtain the door state.And close the door in time.
With dedicated 5-Keypad,the manager can control both doors in emergency.
With 2 dedicated Security Passwords;You can enter the passwords to close both Doors in emergency.
2System Set-up and Main Functions;
This chapter describes basic set-up of the SW3020 Access Control System.Figure 1;
1).Main controller SW3020;
               
The SW3020 is a microprocessor-based Access Control System with many advanced features built in.It is the heart of the system,which housed and the central processor and perform all the control function.And there are a number of connectors at the edge of the controller casing for linking to the other device in the system.This special design make sure the installation more easily.
Feature;
1.Interlock feature;If one door doesn’t close completely,you can’t open the other door.
i.e. If door A doesn’t close,SW3020 voice remind”please close door A”.At the same time,the Card Reader and Push Button of Door B can’t work.After you close the door A,door sensor detect and the SW3020 confirm the signal.Then you can open the Door B.The same of Door B.
2.With 2 dedicated Duress Passwords;You can enter the passwords to close both Doors in emergency.
3.Reset Button;If anyone input the wrong passwords 5 times,the system close both doors for 5 mins and start sound&light alarm.You can recover by Reset Button.
4.In emergency:You can open/close the both doors.
i.e. You can open both doors for fire alarm,smoke alarm and so on.You can close both doors for Bank robbery…
5.Control the lights;Usually there are lights between Door A,Door B.If you open the door,the system can turn on the lights(<400W) for you at the same time.
6.Reset the manager password;If you forget the manager password and can’t operate the system.You can connect the Reset Key(TP1) and turn on the power of SW3020.The 3 lights of SW3020 flash for seconds and send out a long “beep”,release the Reset Key.Then the manager password reset to 88888888.
 
2).5-Keypad;
With dedicated 5-Keypad,the manager can control both doors in emergency.
1.Doors AB open button;In emergency,such as fire alarm,smoking alarm,gas alarm,manager can press the “Doors AB open” button.Door A & Door B both open for 5s,then System Restore.So all the persons can leave the bank quickly.
2.Doors AB close button;In emergency,such as bank robbery, the manager can press “Doors AB close” button to close Door A & Door B.
3.Reset Button;You can use Reset Button to Restore the system.
i.e.Anyone press the wrong password 5times,the doors both close.
In emergency,someone input the Duress password and the doors both close.
4.Door A open & Door B open;You can press “Door A open” or “Door B open” key to open the door.Only make sure the other door is close.
 
3).Reader;
There are 3 main kinds of Readers,IC Readers,ID Readers,Fingerprint Readers.All support the Wiegand 26/34.
                    
ID Readers         IC Readers        Fingerprint Readers.
Normal readers are for reading the ID/IC number encoded on the identification card.Fingerprint Readers are to identify fingerprint of users,which are necessary when the much more secure modes of operation are required,for example:ID/IC card + password.We offer a wide range of readers that may be used in SW3020.
 
4).Door sensor;
The Door sensor is a device for detecting whether the door is open or closed.It is linked to the controller SW3020.
5).Electric Door Lock;
The electric Door Lock is an electromagnetic device used to lock or unlock a door.When the device is “activated”,the door can be opened.When it is “deactivated”,it cannot be opened.There are many different types of door locks in use depending in the type of door it has to control.And for the Bank Access control system,we choose Mute Lock, less noise
Mute Lock DS2066
This is DC12V/20mA New Safe Optimized Mute Lock DS2066, unlock electronically or by hand, flexible switch, low electricity consumption. This Door Locks fit for different kinds of doors. When bolt extends out, the door can be locked normally, because the bolt can amend by itself to cause the latch retract. This Electric Door Lock easy installation onto pocket- type doors with just a simple cut in door edge.
Features;
Automatically lock when closed
Locking dog streches more than 0.79",conforming to GA/T 73-945.6B standard
Used with building interphone and door control systems
Lock life length (> 350,000 times)
Specifications;
Service voltage;DC 12V
Unlocking current;< 300mA
Static current;1 s
Package includes
DC12V/20mA New Safe Optimized Mute Lock       1
Lock Cover                                    1
Installation Fittings                              1
Lockhole                                       1
Keys                                          3
User Manual                                    1
 
6).Push Button;
      
 
The Push Button is a device for staff to exit from inside of the door and is connected to the controller.When staff pushes down the the Push Button,the controller will unlock the door.
 
3System Set-up and Main Functions;
Cable Specification Cecommencation;
1).Cable for power Supply;
24AWG(0.6mm),2 cores for 60m.
22AWG(0.8mm),2 cores for 90m.
18AWG(1.2mm),2 cores for 150m.
 
2).Cable for Wiegand Reader being linked to Controller;
At least 22AWG(0.8mm),screened 4 cores or 6 cores.
 
3).Cable for Other Device being linked to Controller;
At least 11AWG(0.8mm),screened 4-8 cores.
 
4.Product list;
SW3020 Access Controller with Power and Box      1pcs
Readers(ID,IC,Fingerprint all OK)                 2/4pcs
Push Button                              2pcs
Door sensor                              2pcs
Power for Mute Lock                       2pcs
Mute Lock                               2pcs
 
5.Specification;
1. Basic Specification;
Lock Output; 2
Reader Input; 4
Push Button Input; 2
Card response time; <1s (Power stability)
Door Open Time; 0.1s to 25.5s (Depending on your setting)
Door Sensor Input; 2
Alarm Output; 2
Alarm Response Time;0.1s to 25.5s (Depending on your setting)
Fire Alarm Input; 1
(TTL Input; you can choose such as; Smoke Sensor, Gas Sensor, Glass Break Sensor…)
2. Mainframe-box
 Dimension;285mm ×240mm×82mm
 Colour;Black
 Weight;2.2KG
3. MotherBoard
 Demension;195mm×125mm×1.6mm
 Colour;Dark Blue
 Weight;0.2KG
4. Working conditions;
 Work Temperature;-10 ~ 60degree
Storage Temperature;0~ 50degree
Humidity;<95% R.H (non-condensation)
Power;220V/250mA
Bank Interlock Access Control  1Bank Interlock Access Control  2

会员信息

深圳市兆科泰电子有限公司
国家/地区︰广东省深圳市
经营性质︰生产商
联系电话︰13717039740
联系人︰方女士 (销售)
最后上线︰2011/04/01