Specifications : |
AC Input Range : 90~264/277Vac / 0.5A / 47~63Hz |
Operation Temp. : -30℃ ~ +60℃ , Tc : 90 ℃ |
Input Inrush Current : <10A/115Vac,<20A/230Vac |
Storage Temp. : -40 ℃ ~ +85℃ |
|
Power Factor : >0.92 at full load,115Vac,230Vac |
MTBF(@50℃) : >50,000 Hours,MIL-217F |
Surge Immunity : >1KVAC /4KVAC |
|
Safety : cUL1310 Class 2,UL879,CUL , KTL(12V,13V) |
Total Harmonic Distortion : 20% Max. |
|
EN55015 ,EN61547,EN61347-2-13,CE,FCC B, IP66-IEC60529 |
Efficiency : 85% typical |
|
Dimension : 95(L),70(W),32(H) mm |
|
Protection : OCP,SCP - Auto Recovery |
|
Weight : 370 Grams Typical |
|
Model Listing : |
Model |
DC Output |
Output Current |
Watts |
Constant Voltage |
Max. |
Max. |
LP1040-09 |
9V ± 5% |
4450mA |
40W |
LP1040-10 |
10V ± 5% |
4000mA |
40W |
LP1040-12 |
12V ± 5% |
3330mA |
40W |
LP1040-13 |
13V ± 5% |
3080mA |
40W |
LP1040-15 |
15V ± 5% |
2680mA |
40W |
LP1040-18 |
18V ± 5% |
2220mA |
40W |
LP1040-22 |
22V ± 5% |
1820mA |
40W |
LP1040-24 |
24V ± 5% |
1670mA |
40W |
LP1040-36 |
36V ± 5% |
1110mA |
40W |
LP1040-48 |
48V ± 5% |
830mA |
40W |
Model |
DC Output |
Output (Note1) |
Watts |
Working Voltage |
Constant Current |
Max. |
LP1040-09-C4450 |
6 ~ 9V |
4450mA ± 5% |
40W |
LP1040-10-C4000 |
6 ~10V |
4000mA ± 5% |
40W |
LP1040-12-C3330 |
7~12V |
3330mA ± 5% |
40W |
LP1040-13-C3080 |
7~13V |
3080mA ± 5% |
40W |
LP1040-15-C2680 |
9~15V |
2680mA ± 5% |
40W |
LP1040-18-C2200 |
9~18V |
2200mA ± 5% |
40W |
LP1040-22-C1820 |
12~22V |
1820mA ± 5% |
40W |
LP1040-24-C1670 |
12~24V |
1670mA ± 5% |
40W |
LP1040-36-C1100 |
18~36V |
1100mA ± 5% |
40W |
LP1040-48-C0830 |
26~48V |
830mA ± 5% |
40W |
Note1 : Constant Current can be set from 50% to 100% to meet user requirement. |