portable ventilator HX-130

portable ventilator HX-130
Model:HX-130
Brand:custodi medical
Origin:Made In China
Category:Home Supplies / Personal Care Appliance
Label:portable ventilator , medical ventilator , medical ventilators
Price: -
Min. Order:1 pc
Inquire Now

Product Description


Operating Modes


 


Volume Control Ventilation (VCV),Assisted/Controlled Pressure Control Ventilation (PCV),


Assisted/Controlled Pressure Support Ventilation (PSV),


SIMV(VCV)+PSV


SIMV(PCV)+PSV


Mandatory Minute Ventilation (MMV)


 


Parameter Selection according to the operating mode


 


FiO2: 21% to 100%


PEEP/CPAP: 0 to 40 cmH2O


Inspiratory Sensitivity:


Flow triggered: 0.5 to 20 L/min, OFF


Pressure triggered: -1 to -20 cmH2O, OFF


Tidal Volume: 20 to 2000 mL


Breath frequency: 1 to 100 bpm


I:E Ratio: 5.0 : 1 to 1 : 5.0


Inspiratory plateau: 0 to 50%


Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave


SIGH: 1.0 to 2.0


Breath frequency(SIMV): 2 to 40bpm


Inspiratory time (SIMV): 0.1 to 12 S


Pressure Support Ventilation (PSV): 0 to 40 cmH2O


Expiratory Sensitivity for PSV : 10% to 75% of the initial flow


Maximum Inspiratory time (PSV): 1.0 to 8.0 S


Pressure Control Ventilation(PCV): 0 to 40 cmH2O


Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL


Backup Rate (PSV): 2 to 40 bpm


Object Tidal Volume(MMV): 20 to 2000 mL


Ventilation volume(MMV): 0.5 to 40.0 L/min


 


Alarms


 


High tidal volume


Low tidal volume


High minute ventilation


Low minute ventilation


High respiratory rate


Low respiratory rate


High peak pressure


Low peak pressure


High PEEP pressure


Low PEEP pressure


Low pressure of one gas (oxygen or air)


Apnea


AC power fail


Battery disconnect


Low battery Circle block


 


OTHER FEATURES AND CONTROLS


 


12.1 TFT


Pressure vs time curve


Flow vs time curve


Volume vs time curve


Pressure vs volume loops


Flow vs volume loops


Scale of graphics


Nebulizer


 


POWER REQUIREMENT


 


Main power: from 85 to 265VAC 47-63HZ


Automatic voltage switch


Internal battery: 12VDC; 7AH


Automatic recharge.


Estimated duration: more than 2 hours when completely charged.


The display shows an icon with the charge level.


 


PNEUMATIC REQUIREMENT


 


Oxygen: pressure 2.8 to 6 bar ISO5359 connector


Air: pressure 2.8 to 6 bar ISO 5359 connector

portable ventilator HX-130 1

Member Information

Beijing Custodi medical equipment technology Co.,Ltd.
Country/Region:Beijing - China
Business Nature:Manufacturer
Phone:21698306
Contact:Mike (manager)
Last Online:23 Dec, 2011