NGR High Voltage Neutral Point Generator Distribution Resistance Box

NGR High Voltage Neutral Point Generator Distribution Resistance Box
Model:MRD-BJ1
Brand:MINGRUI
Origin:Made In China
Category:Electronics & Electricity / Power Supply & Distribution / Power Distribution Cabinet
Label:ngr , power distribution , transformer
Price: US $4000 / pc
Min. Order:1 pc
Inquire Now

Product Description

NGR Introduce 

Neutral Grounding Resistors are used to protect power transformers, power generators and other associated equipment in your power systems against 50/60 Hz faults (short circuit) and transient phenomena (lightning).

SPECIFICATIONS   (Order Note)

There are six parameters needed to specify the neutral grounding resistor.
1. Rated voltage line to neutral or system voltage.

2. Rated fault current.

3. Rated “duration time” of the line to neutral voltage not exceeding the allowable temperature rise.

4. Rated Resistance.

5. Application environment, indoor or outdoor.

6. Enclosure material, ss plate or normal cold rolled sheet.

Rang Parameters

• Rated current: from 1 amp to 2000 A

• Rated voltage: from 0.4 to 35kV

• Rated Resistance: from 1 ohm to 2000 ohm

• Rated time: 1 sec to continuous time rating

Technology Quality 

with IEEE-32. Routine tests performed on each Neutral Grounding Resistor are measurement of resistance, high voltage power frequency, insulation measurement, aspect verification, dimensional control. Mingrui’s internal quality system has been developed and certified under ISO 9001 quality system

Standard 

Standard unit includes the stainless steel resistor assembly plus all the required insulators, internal connections and hardware installed in a standard safety enclosure. Neutral Grounding Resistor units are completely assembled, prewired, and tested at our facility. For shipping all units are crated for added protection and ease of handling.

Enclosure Options 

•Stainless steel, cold rolled plate construction. Custom paint finish is available.
• Top or side mounted entrance bushing(s).
• Screened covers for indoor applications.
• Support stands for elevating the enclosure above ground.

OPTIONS

Current or potential transformers mounted and prewired at our facility

ON or OFF Load disconnecting switches



Notice for purchase

1. system rated voltage

2.short-time withstand current;

3. normal resistance; 

4. with current transformer or not; transformation ratio, capacity and compound deviation of the current transformer;

5. method of wiring (optional): a. wire in from the top, and out at the bottom, b. wire in and out from the bottom, c. wire in and out from the side, d. wire in from the side and out at the bottom; 

6. durable time for short-time withstand current; 

7. material of resistance cabinet, protection grade of (IP), color code and installation site of the resistor cabinet; 

8. with earthing record and temperature and humidity control equipment or not

NGR High Voltage Neutral Point Generator Distribution Resistance Box 1NGR High Voltage Neutral Point Generator Distribution Resistance Box 2NGR High Voltage Neutral Point Generator Distribution Resistance Box 3

Member Information

Baoding Mingrui Optoelectronics Technology Co.LTD
Country/Region:He Bei - China
Business Nature:Manufacturer
Phone:13315298626
Contact:Mery Miao (Overseller)
Last Online:26 Apr, 2012