Product Description

HVAC Plate Heat Exchangers Helium Leak Testing System

 

The automatic helium leak test system is suitable for the detection of the airtightness of the plate- heat exchanger, which is helpful for many industrial applications such as petroleum industry, papermaking, power generation, textile, HVAC, metallurgy, organic chemistry and automobile.

The system adopts duplex structure, places the workpiece in the inner leak testing station to process inner leak detection firstly, and then push the product to outer leak testing station through the transmission line to process detection. For the three-cavity workpiece, during the inner leak testing cycle, the system fill helium into A cavity for detecting the leakage between A- B and A – C. And during the outer leak detection cycle, the system can detect the leakage of the cavities. This system comes with helium recovery device, can save the cost of helium effectively.

 

Technical Parameters

Workpiece

Plate Heat Exchanger

Leak testing station

Two Stationsone is  for workpiece strength and inner leak test ,the other is for outer leak test

Size of testing chamber 

850*750*400mm

Can be installed a large workpiece (620 * 500 * 250mm) or 2 small workpieces (320*100*77mm)

Gas for Gross Leak Test

Nitrogen

Nitrogen leakage pressure

5.5MPa

Gas for Fine leak test

100% Helium

Helium leakage pressure

5.0MPa

Reject point

5.0E-7Pa.m3/sec.

Cycle time

It takes 8 hours to check 480 small workpieces or 240 large workpieces

Helium recovery rate

≥98%