ICU Ventilator

ICU Ventilator
Model:SHB-2000C
Brand:SAFEHEART
Origin:Made In China
Category:Services / Therapies
Label:ICU ventilator , respiration , medical ventilator
Price: -
Min. Order:-
Inquire Now

Product Description

Feature

 Advanced ICU Ventilator with high-technology
 Pneumatically driven and electronically controlled
 12.1″TFT touch screen with advanced technology
 Multi-ventilation modes better for patient monitoring
 Suitable for pediatric and adult with wide volume
 Multi- alarms setting for safety guarantee
 Built-in battery for long time assistance
 Loop functions of P-V & F-V
 Special nebulization function
 Interface for RS232 ,USB and VGA

Technical Specification:
Specification:

 Volume Controlled (VCV), Assist/Control
 Pressure Controlled (PCV), Assist/Control
 Synchronized Intermittent Mandatory Ventilation (SIMV)
 Volume-controlled breaths (V-SIMV)
 Pressure-controlled breaths (P-SIMV)
 Pressure Support Ventilation (PSV)
 Spontaneous Ventilation (SPONT)
 Continuous Positive Airway Pressure (CPAP)
 Bi-level Positive Airway Pressure (BIPAP)
 Combined: VCV+SIGH, SIMV(VCV)+PSV, SIMV(PCV)+PSV

Parameter:

 Tidal volume: 20~1500ml
 Respiratory rate: 1~100bpm
 Inspiration time: 0.1~12s
 Inspiration pause time: 0~4s
 FiO2: 21~100%, OFF
 Trigger sensitivity: Pressure(-2~0kPa, above PEEP)
 Flow (0.5~20LPM, with base flow)
 PEEP: 0~5kPa
 Psupport: 0~7kPa
 Pcontrol: 0.5~7kPa
 Phigh: 0.5~7kPa
 Plow: 0~5kPa
 E-sense (Option): 10%~60%
 100%O2 (Option): 2min
 Inspiration hold (Option): Yes
 Expiratory hold (Option): Yes
 Manual inspiration (Option): Yes
 Freeze(Option): Yes
 Nebulizer(Option): 30 minutes
 Key lock: Yes
 EtCO2 .Pulse Rate.SPO2.FiCO2

Monitoring:

 Pressure values: Paw, Pplat, Pmean, PEEP
 Volume/Flow values: VTi, VTe, MV, MVspont
 Time Values: Ftotal, Fspont, I:E
 Oxygen monitoring: With O2 sensor (option), without O2 sensor
 Real time curves: Pressure-Time, Flow-Time, Volume-Time, Pressure-Volume Loop, Flow-Volume Loop,SPO2-Time,EtCO2-Time.
 Respiratory mechanics, Dynamic and static compliance, Resistance, Auto PEEP

Alarm:

 MVhigh, MVlow, Circuit disconnected, Paw high, Paw low, Airway Pressure High, VTe high, Pspont high, Tapnea, FiO2 low, Power Supply Failure, Nebulizer on, Battery Low, Battery Exhausted, Air Supply Down, O2 Supply Down, Air&O2 Supply Down

Technical Data:

 Screen: 12.1″TFT touch screen
 Gas supply: O2, Air (0.28~0.6MPa)
 Power supply: AC110~240V, 50Hz/60Hz, 80VA
 Maximum security pressure: 8kPa
 Compliance: 4ml/100Pa
 Noise: 65dB(A)
 Communication interfaces: RS232, VGA port

Environment requirement:

 Temperature: 5℃~40℃(Operation)
              -10℃~55℃(Storage)
 Relative humidity: ≤80%, non-condensing (Operation)
                    ≤93%, non-condensing (Storage)
 Atmospheric pressure: 86~106kPa (Operation)
                       86~106kPa (Storage)
 Atmospheric operation: 500~800mmHg/3565~-440m(Operation)
                        375~800mmHg/5860~-400m(Storage)

ICU Ventilator 1

Member Information

Beijing Safeheart Medical System LTD
Country/Region:Beijing - China
Business Nature:Manufacturer
Phone:18210188071
Contact:Sammy Lee (Regional Manager)
Last Online:08 Jun, 2012