Flame photometer(can test K,Na)

Flame photometer(can test K,Na)
Model:AE-SFP40
Brand:A&E Lab
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Analysis Instrument
Label:spectrophotometer , lab instrument , flame photometer
Price: -
Min. Order:1 pc

Product Description

A & E Lab.

Main Products: Atomic Absorption Spectrometer (AAS), Fluorescence Spectrophotometer, Bio-Spectrophotometer, UV Vis Spectrophotometer, Visible Spectrophotometer, Flame Photometer, Whiteness Meter, Turbidity Meter, Colorimeter, Gloss Meter, Tintometer, Automatic Polarimeter, Auto Melting Point Apparatus, Automatic Refractometer, Abbe Refractometer, PH/DDS/TDS Meter, etc.

Key Features:
* Duel channel, LCD display.
* Pre-selection of flame sizes;
* A flameout protection device;
* K and Na testing at the same time.

Applications:
Flame Photometer is used for analyzing & measuring the content & concentration of K, Na elements.
* Testing cement, glass, ceramics, refractory materials and other construction materials;
* Testing fertilizers and soil;
* Testing products of mining, petroleum, metallurgy, and chemical products;
* Testing pharmaceutical, beverages and other food;
* MSW testing;
* Various laboratory tests for scientific research, health, education and other fields.

Ordering Information:

AE-SFP40  With air-compressor.Measurement Range:K: 0-15, 0-40ug/mL;  Na: 0-40, 0-80ug/mL.

AE-SFP60  With air-compressor. Measurement Range:K: 0-15, 0-40, 0-60ug/mL;  Na: 0-40, 0-80, 0-120ug/mL.

AE-SFP100 With air-compressor, micro-printer or PC software.

                    Measurement Range:K: 0-15, 0-40, 0-60, 0-100ug/mL;  Na: 0-40, 0-80, 0-120, 0-160ug/mL.

Technical Specifications:

Linearity Range:K: detection limit ≤ 0.004mmol/L; Na: detection limit ≤ 0.008mmol/L

Linearity Error:K: ≤ 0.005mmol/L(0.0100~0.0800)mmol/L;Na: ≤ 0.03mmol/L(0.0500~0.400)mmol/L.

Repeatability:Conduct 7 consecutive independent tests for one standard solution,the relative standard deviation: ≤ 3%.

Stability:Continuous sampling of standard solution, the biggest change in the relative volume in 15s: ≤ 3%;
              Test once every minute, and test 6 times in total, the biggest change in the relative volume: ≤ 15%.

Response Time:Response time <8s;

Suction Jet of Samples:Suction jet of samples <6mL/min;

Dimension:380x770x570mm;

Weight:18kg.