GF6018A Clamp Type Multimeter Calibration Device
Introduction
The device is according to verification regulation JJG124-2005 "ammeter, voltmeter, power table and resistance meter calibration regulations, JJF1075-2001" clamp ampere ammeter calibration the requirements of the "standards for the design of 0.05 magnitude ac and dc standard units. The source of the signals of the DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave source. The display USES graphics standard 240 x 128 LCD monochrome screen, chart characters, showed clear. Circuit design perfect protection, reliable operation, easy to operate.
Main functions and features
1. The device consists of a single-phase ac voltage standard resource, current standard resource and dc voltage, current standard resource of standard resource.
2. Have calibration function, which can according to the standard of external value, fixed standard resource output values.
3. The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
4. Manual and semi-auto inspection 0.2% and below levels of digital multimeter, an analogue meter installation type digital instrument, including dc analog output of digital instrument; All kinds of clamp ampere ammeter; Verification clamp ampere ammeter range for 200 A, 600 A, 1000 A.
5. To generate containing 2 ~ 31 harmonic wave distortion, the harmonic number, number, amplitude and phase of the harmonic wave to base wave all can be programmed control.
6. With RS232 interface and large capacity non-volatile memory, can store 500 blocks are inspection table test data. Through the PC software, the PC control this device automatic and manual inspection, and the results are processing and management.
Technical Data
AC output
Voltage range  200 mV, 400 mV, 2 V, 4 V, 20 V, 100 V, 200 V, 500 V, 1000 V;
Current range 20μA, 40μA, 200 μ A, 400 μ A, 2 mA, 4 mA, 20 mA, 40 mA, 0.2 A ,0.5 A, 2 A, 5 A, 10 A, 20 A;
Clamp ampere ammeter range: 200 A, 600 A, 1000 A;
Adjusting range 0 ~ 120% (1000 V voltage except);
Adjust fineness 5 x 10-5;
Voltage, current output capacity 20 VA;
Voltage, current adjustment for accuracy
± (0.03% RD + 0.02% FS);
Voltage, current output stability0.01% / 60 s;
Voltage, current waveform distortion degree0.3%;
Sine wave output frequency range (45-65) N Hz (N = 1, 2, 3,...... 31);
Sine wave frequency output fineness 0.001 N Hz (N = 1, 2, 3,...... 31);
Phase adjustment range 0 ~ 359.99 °;
Phase adjust fineness 0.01 °;
Harmonic output 2 ~ 31, range 0 ~ 20% (base wave ratings);
Harmonic phase fineness 0.01 ° N (N for harmonic frequency, N = 2 and 4,...... 31);
Output can also contains multiple harmonics, also can set base wave amplitude is 0, output power frequency than the sine wave.
DC output
Voltage range  200 mV, 400 mV, 2 V, 4 V, 20 V, 40 V, 100 V ,200 V , 400 V ,1000 V;
Current range  20μA, 40μA, 200 μA, 400 μ A, 2 mA, 4 mA, 20 mA, 40 mA, 0.2 A, 1 A, 2.5 A, 5 A, 10 A, 20 A;
Voltage, current, adjusting range 0 ~ 120% (1000 V voltage except);
Voltage, current  adjust fineness 5 x 10-5;
Voltage output capacity 20 W;
Current output capacity of 30 W;
Voltage, current adjustment for accuracy ± (0.03% RD + 0.02% FS);
Voltage, current output stability 0.01% / 60 s;
Voltage, current output ripple1%.
Frequency output
Sine wave output range (using AC voltage, current output provide)
(45-65) N Hz (N = 1, 2, 3,...... 31);
Fineness 0.001 N Hz (N = 1, 2, 3,...... 31);
The setting accuracy 5 x 10-5;
Point 1 KHz square wave frequency output, 5 KHz, 10 KHz, 50 KHz, 100 KHz, 200 KHz, 1000 KHz;
Square wave amplitude 4.5 V.
Electronic resistance box output
Quantity process
0 ~ 200 Ω, 200 ~ 400 Ω, 0 ~ 2 K Ω, 2 K Ω ~ 4 K Ω, 0 ~ 20 K Ω, 20 K Ω ~ 40 K Ω, 0 ~ 200 K Ω, 200 K Ω ~ 400 K Ω, 0 ~ 2 M Ω, 2 M Ω ~ 4 M Ω;
Fineness 0.025%;
Setting accuracy ± (0.12% RD + 0.08% FS).
Work power
single-phase 220 V±10%, frequency 50 HZ ±5%.
Use of the environment
temperature 20± 10, relative humidity85% RH.
Volume and weight
 440 mm x 450 mm x 160 mm, about 12 kg

Clamp Type Multimeter Calibration Device  1