Model |
APC 1000W |
APC 2000W |
APC 3000W |
APC 4000W |
APC 5000W |
APC 6000W |
Inverter Output |
Continuous Output Power |
1000W |
2000W |
3000W |
4000W |
5000W |
6000W |
Surge Rating(20s) |
3000W |
6000W |
9000W |
12000W |
15000W |
18000W |
Capable of Starting Electric Motor |
1HP |
2HP |
3HP |
4HP |
5HP |
6HP |
Output Waveform |
Pure Sine wave/Same as input(Bypass mode) |
Nominal Efficiency |
>88%(Peak) |
Line Mode Efficiency |
>95% |
Power Factor |
0.9-1.0 |
Nominal Output Voltage rms |
110V/120/220V/230/240VAC |
Output Voltage Regulation |
±10% rms |
Output Frequency |
50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Short Circuit Protection |
Yes, Current Limit Function (fault after 1s ) |
Typical transfer Time |
10ms(Max) |
THD |
less than 3% |
DC Input |
Nominal Input Voltage |
12V |
24V |
48V |
Minimum Start Voltage |
10V |
20V |
40V |
Low Battery Alarm |
10.5V |
21V |
42V |
Low Battery Trip |
10V |
20V |
40V |
High Voltage Alarm & Fault |
16V |
32V |
64V |
High DC Input Recovery |
15.5V |
Low Battery voltage recover |
13V |
26V |
52V |
Idle Consumption-Search Mode |
< 25 W when Power Saver On |
Charge |
Input Voltage Range |
95-127VAC |
194-243VAC |
164-243VAC(W) |
Output Voltage |
Depends on battery type |
Charger Breaker Rating |
10A |
10A |
20A |
20A |
30A |
30A |
Max Charge Rate |
35A / 70A |
Battery Initial Voltage for Start Up |
2V-15.7V for 12V( *2 for 24V, *4 for 48V) |
Over Charge Protection Shutdown |
15.7V for 12V (*2 for 24V, *4 for 48V) |
Charger curve(4 stage constant current)Battery types 4 step digital controlled
progressive charge
|
Battery type |
Fast V Float V ( *2 for 24v, *4 for 48v) |
Gel U.S.A |
14 |
13.7 |
A.G.M 1 |
14.1 |
13.4 |
A.G.M 2 |
14.6 |
13.7 |
Sealed Lead Acid |
14.4 |
13.6 |
Gel Euro |
14.4 |
13.8 |
Open Lead Acid |
14.8 |
13.3 |
Calcium |
15.1 |
13.6 |
De-sulphation |
15.5 for 4hrs |
Remote Control |
Yes. Optional |
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) |
Nominal Voltage |
110VAC/120VAC |
230VAC |
Low Voltage Trip |
80V/90V±4% |
184V/154V±4% |
Low Voltage re engage |
90V/100V±4% |
194V/164V±4% |
High Voltage Trip |
140V±4% |
253V±4% |
High Voltage re engage |
135V±4% |
243V±4% |
Max Input AC Voltage |
150VAC |
270VAC |
Nominal Input Frequency |
50Hz or 60Hz (Auto detect) |
Low Freq Trip |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz |
Low Freq re engage |
48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz |
High Freq Trip |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz |
High Freq re engage |
54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz |
Overload protection |
Circuit breaker |
Output Short circuit protection |
Circuit breaker |
Bypass breaker rating |
10A |
20A |
30A |
30A |
40A |
40A |
Transfer switch rating |
30amp for UL & TUV |
40amp for UL |
Max bypass current |
30amp |
40amp |
Bypass over load current |
35amp: Alarm |
45amp: Alarm |
Mechanical Specifications |
Mounting |
Wall mount |
Inverter Dimensions(L*W*H) |
382*218*179mm |
442*218*179mm |
598*218*179mm |
Inverter Weight |
16KG |
20KG |
24KG |
35KG |
45KG |
45KG |
Shipping Dimensions(L*W*H) |
520*315*300mm |
580*315*300mm |
740*315*300mm |
Shipping Weight |
18KG |
22KG |
26KG |
37KG |
47KG |
47KG |
Display |
Status LEDs / Status LEDs+LCD |
Standard Warranty |
1 Year |