Model: | S1100 |
---|---|
Brand: | SANCH |
Origin: | Made In Taiwan, China |
Category: | Electronics & Electricity / Transducer |
Label: | VFD , AC Drive , frequency converter |
Price: |
-
|
Min. Order: | 1 pc |
More professional control program
Professionally customized core computing program,Smooth shift on forward and reverse rotaion,Automatic torque compensation,Automatic slip compensation.
Lower heat
Advanced control technology of switching 3-phase to 2-phase,reduces heat by 33.3%.
Faster computing speed
Adopting nanometer manufacturing technology, CPU with built-in dual core makes the computing speed dramatically improve.
More excellence performance
A variety of customized functions bring maximum benefits and convenience to users.
Reliability
·Protect function:over voltage(OU),low voltage(LU),over current(OC),over heat(OH),over load(OL)
·Over voltage and over current stall prevention
·The technology of integration hardware and software wave filtering for better anti-jamming effects
·3-level prohibited frequencies can avoid resonance effectively
·Braking using software control,be able to adjust brake-bit and brake occupating coefficient
High performance
·Automatic torque compensation-start torque can be up to 150% at 2HZ
·Aautomtic slip compensation-more accurate speed
·Ultra-low noise-motor runs more stably
·High overload capacity-150% rated torque can last for 65 senconds
Multi-function
·PID feedback control
·Oscillation frequency function
·Built-in PLC enables 16-level speed program running
·Multifarious frequency input methods:pules input,AVI/ACI superimposed,UP/DOWN,RS-485 and so on.
·Multifarious control methods:operation control,exterior terminal two-line/three-line control,RS-485 control.
·Multifarious stop methods(OFF stop,stop for AVI zero)
·Multifarious input methods:external EF,couting input,frequency switching,Pendulum frequency input and so on.
·Multifarious output methods:multi-function relay output,multifunction collector open circuit output
Multifarious output methods:indication of forward and reverse rotation,counting arrival,program
·operation,and faults.
Other functions: power failure memory,running-locked when power on,automatic voltage
·regulation(AVR),DC brake,password protection
Thyristor power controller
SPC3 series full-digital three phase Thyristor power controller Which integrates functions of open loop,constant voltage,current,power,power regulation (pass zero) control,control into one and adopting full-digital design to optimize hardware design and strengthen software function can be applied widely to control and regulate three phase,current.power in various industries.Standard communication interface equipped on the controller can meet requirements of high accuracy control. Therefore, it is suitable for resistive load, inductive load and transformer primary side.
Main features
High integration
With integrates functions of control.display and exterior fittings into one is connected easily and operated conveniently.
Phase shift and voltage regulation:adopt phase shift and voltage regulation within short time after starting(soft starter)
Pass zero power regulation:reduce harmonic pollution to power grid
LZ control can avoid current impact influenced by load which is caused by great various between cold status and hot status of resistance to controller and power grid.
Full digital high accuracy phase shift trigger(phase shift accuracy:1000 graduations per 180 degree)
Various control modes
Six control modes: open loop constant voltage,constant current,constant power,power regulation (pass zero) control.LZ control;It can be used flexible to reach an optimized load control.
Constant voltage,constant current,constant power can be controlled by effective value.
Strong programmable function
Able to on-line setting debug 118 parameters through Modbus communication. Can meet individuation requirements of various industries in largest extent.
Mighty anti-interference ability
Adopting isolation technology in output and input with anti-interference ability.
Safe and reliable operation
User can operate the device safely and reliably because the device is equipped with safety isolation in control , power part relay output warning and twice rating current protection and SCR overheat prevention.
Input Voltage |
220V |
440V |
|||||||||||||
Model number: S1100-2T/4T□□□G |
0.75 |
1.5 |
2.2 |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
||
Output |
Applicable motor power (KW) |
0.75 |
1.5 |
2.2 |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
|
Output rated current (A) |
5.0 |
6.5 |
11 |
3.0 |
4.2 |
5.5 |
8.2 |
13 |
18 |
24 |
32 |
38 |
45 |
||
Max output voltage (A) |
Input power |
||||||||||||||
Over load capacity |
150% of rated current and run for 65 seconds |
||||||||||||||
Power |
Phase . Voltage . Frequency |
1-phase/3-phas 200-240V 50/60HZ |
3-phas 380-460V 50/60HZ |
||||||||||||
Allowable variation range of Voltage Frequency |
Voltage: ±15% Frequency: ±5% |
||||||||||||||
Input current (A) |
11/7.4 |
15/10 |
27/15 |
4.2 |
6.0 |
7.2 |
8.5 |
14 |
20.6 |
28 |
30 |
39 |
49 |
||
Controlling Characteristics |
Control mode |
Adopting SVPWM modulating techniques(V/F control and Speed Sensor-less Vector) |
|||||||||||||
Output range of frequency |
0.01~400.0Hz |
||||||||||||||
Frequency setting analyzing degree |
0.01Hz |
||||||||||||||
Output frequency analyzing degree |
0.01Hz |
||||||||||||||
PWM load wave frequency |
Available to modulate from 2 to 10kHz |
||||||||||||||
Torque increase |
Auto torque-increase and auto slip compensation at 2 Hz the starting torque can reach 150% of rated torque. |
||||||||||||||
Jog frequency |
3 points can be set from 0.01 to 400.0Hz |
||||||||||||||
Acceleration/deceleration time |
0.01 to 600.0 seconds. (2 steps of accel/decel time can be set separately.) |
||||||||||||||
Stall Prevention Level |
According to the load characteristics of motor, it’s available to be set as 50 to 200% of the rated current of the drive |
||||||||||||||
DC braking |
According to be operated from 0.01 to 400.0 Hz from STOP, braking 0 to 100% of the rated current. Starting time 0.0 to-60.0 sec, Stopping time 0.0-60.0 sec |
||||||||||||||
Braking torque |
20% (125% shall be available if connected with purchase braking resistor externally) (or 1 to 25HP, equipped within the electric crystals, for 30 HP, braking unit module shall be connected externally.) |
||||||||||||||
V/F curve |
V/F curve available to be set |
||||||||||||||
Operation characteristics |
Frequency setting signal |
Digital Operator |
Set by UP and DOWN |
||||||||||||
External terminals |
0-10VDC, 4-20mADC, Series Communication Board (RS-485) |
||||||||||||||
Running operatisignal |
Digital Operator |
Available to be operated by RUN, STOP and JOG keys. |
|||||||||||||
External terminals |
2 wire style (Fwd/Stop, Rev/Stop, Run/Stop and Fed/Rev) /3 wire operation, JOG running, Serial Communication Board(RS-485) |
||||||||||||||
Intelligent Input Terminal |
Switching of 16 step pre-set available speed; Switching of First/Second acceleration/deceleration time; prohibiting acceleration/deceleration and external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption. |
||||||||||||||
Intelligent Output Terminal |
During running, frequency agreement output, non-zero count agreement output, over torque output, external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption. |
||||||||||||||
Analog signal output |
Correspond to actual output frequency or output current. |
||||||||||||||
Fault signal contact |
Contact of ON at AC motor drive (Relay with one C contact or two open collector output.) |
||||||||||||||
Built-in Function |
Setting max/min output frequency; momentary power off restarting; setting of S curve acceleration/deceleration time; auto-voltage stabilizing output modulation; digital frequency output signal; fault records; parameters locking; reset to factory setting; inhibiting reverse run; over current stalling prevention, over voltage stalling prevention, electrical thermal relay. |
||||||||||||||
Protection Function |
Over current; over voltage, low voltage; external fault interruption input; motor over load; GFF: grounding protection(For optional use); over load of the drive and drive overheating |
||||||||||||||
Digital operator |
Consisting of 8 functional keys, 7 step LED in 5 digits; 5 status LED indicators. Available to set frequency, display actual output frequency, output current, self-determined unit parameter overview of users, modify settings and for parameter locking, fault displaying. Available to perform running, stop, reset, fwd/rev run and jog run. |
||||||||||||||
Environment |
Operational Environment temperature |
-10℃ to +50℃ (+40℃ ~ +50℃ available when the dust cover is removed) |
|||||||||||||
Storing temperature |
-20℃ to + 60℃ |
||||||||||||||
Installation height |
Lower than 1000m, without corrosive gas, fluid and dust. |
||||||||||||||
Vibration |
Below 20Hz 9.80665m/s² (1g), 20~50 Hz 5.88m/s² (0.6g) |
||||||||||||||
Protection degrees |
Determined by the installation environment of the end-users. |
Quanzhou Machtric Automation Equipment Co., Ltd | |
---|---|
Country/Region: | Fu Jian - China |
Business Nature: | Manufacturer |
Phone: | 22555211 |
Contact: | Sendy (sales) |
Last Online: | 24 Dec, 2012 |