Features:

  • Single or Twins Ultrasound transducer
  • Data Graph and Trend Table Review of both mother and fetal
  • Built-in thermal printer
  • Built-in Network capability for connect with central monitoring software
  • Programmable alarms
  • All the colors and looks or the parameters can be customsized
  • Multi-face views, select focus on mother or fetal
  • Storage of patient information and data

Performance Specifications:

  • Display:8.4" Color TFT
  • Resolution:640x480
  • Display Mode:Standard View,Fetal View,Mother View
  • Indicator:Power indicator light, Alarm sound
  • Interface:Socket for connecting fetals FHR, TOCO, and Fetal Movement sensorSocket for connecting mothers ECG, NIBP and   SPO2 sensor.Net Socket(RJ45) for communication cable with Central Monitoring Station Sofrware.
  • Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA
  • Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
  • Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.
  • Alarm:Ajustable High and Low limits. Three level audible and vistual alarm.
  • User Configuration:All the color of parameters and waves can be set according to users willing.

Technical specifications:

  • Safety
  • Meet the requirment of IEC60601 series
  • Type of Protection:Class II with internal electirc power supply
  • Degree of Protection:BF
  • Dimention and Weight
  • Dimention:92(W)x82(H)x22(D)mm
  • Weight:136g(with battery)
  • Operation Environment:
  • Temperature:0℃~ +40℃
  • Humidity:15% ~ 95%
  • Storage Environment:
  • Temperature:-20℃~ +60℃
  • Humidity:10% ~ 95%        
  • Patient Range:Pregnant Adult

FHR:

  • Ultrasound Frequency:2MHz
  • Range:50 ~ 210 bpm
  • Resolution:1bmp
  • Accuracy:±2bmp

TOCO:

  • Range:0 ~ 100%
  • Resolution:1%
  • Non-linear Error:<=±8%
  • Zero control:Manual

FETAL   MOVEMENT:

  • Manual fetal movement mark

SPO2:

  • Measurement Range:0 ~ 100%
  • Resolution:1%
  • Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
  •                  ±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified
  • Alarm Range:0% ~ 100%
  • Refreshing Rate:1s

Pulse  Rate:

  • Measurement Range:25 ~ 250 bpm
  • Resolution:1bpm
  • Accuracy:±3 bpm (non-motion)
  • Alarm Range:25 ~ 250 bmp
  • Refreshing Rate:1s

ECG:

  • Lead mode:3-lead or 5-lead
  • Lead selection:I, II, III, AVR, AVL, AVF, V
  • HR range:15 ~ 300 bpm
  • ECG Waveform:2 channals
  • Accuracy:±2bpm or ±2%, which is greater
  • S-T segment detection range: -2.0mv ~ +2.0mv
  • Arrhythmia analysis: 13 kinds of arrhythmia
  • Alarm Range:15 ~ 300 bpm

NIBP:

  • Method:Oscillometry
  • Mode:Manual/Auto/Contiuous
  • Measurement Range:25 ~ 260mmHg
  • Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes
  • Resolution:1mmHg
  • Overpressure Protection: 300mmHg
  • Alarm range:25 ~260mmHg