Model: | TC,TC-ER,VNTC |
---|---|
Brand: | qingkai |
Origin: | Made In China |
Category: | Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable |
Label: | TC/VNTC/TC-ER , UL 1277 tray cable , Power and control |
Price: |
¥1
/ M
|
Min. Order: | 1 M |
The power TC cable is used to supply power to motors, or for the connection of other power devices in industrial settings.
The power TC cable is listed for direct burial and for use to Class 1, Division 2 hazardous locations and Class control circuits.
PVC-nylon insulation
PVC jacket
90° C, 600 V
Tech. Info & Standards:
SPECIFICATIONS:
1. CONDUCTORS: Class B stranded bare copper per UL 83 and 62.
2. INSULATION: Polyvinyl chloride (PVC) per UL 62 for Type TFFN (18-16 AWG) or UL 83 for Type THWN or THHN wire. Average thickness is 15 mils for sizes 18-12 AWG and 20 mils for 10 AWG.
3. INSULATION JACKET: Each insulated conductor is jacketed with nylon meeting UL 62 for Type TFFN or UL 83 for Type THWN or THHN wire. Minimum thickness is 4 mils.
4. COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2).
5. ASSEMBLY: Conductors are cabled with fillers where necessary to make round. Two conductor cables are flat.
6. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC) per UL 1277.
7. STANDARDS: Tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. Cables are listed for direct burial and meet the IEEE 1202, UL 1277 and ICEA 70, 000 BTU Flame Tests.
8. AMPACITY: Based on not more than three conductors in receway or cable or earth with an ambient temperature of 30C per NEC 310-16. The values have been derated where applicable.
9. TEMPERATURE: 90C
10 VOLTAGE: 600V
Applications:
Designed for power and control, telemetering, relay control, traffic control, switching, lighting and signal transmission. May be used in Class 1, Div. 2 Hazardous Locations per NEC Art. 501. These cables also conform to Art. 318 "Cable Trays" and Art 340 "Power and Control Tray Cable. "
Specifications:
CONDUCTORS: Class B stranded bare copper per UL 83 and 62
INSULATION: Polyvinyl Chloride (PVC) per UL 62 for Type TFFN (18-16 AWG) or UL 83 for Type THWN or THHN wire, nominal thickness is 15 mils for sizes 18-12 AWG and 20 mils for 10 AWG
INSULATION JACKET: Each insulated conductor is jacketed with nylon meeting UL 62 for Type TFFN or UL 83 for Type THWN or THHN wire, minimum thickness is 4 mils
COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2)
ASSEMBLY: Conductors are cabled with fillers where necessary to make round, two conductor cables are flat
OVERALL JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277
STANDARDS: Meets UL requirements for Type TC cables having THWN or THHN (TFFN) conductors, cables are listed for direct burial and meet the IEEE 1202, UL 1277 and ICEA 70, 000 BTU Flame Tests
AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30C per NEC Table 310.16, the values have been derated where applicable
TEMPERATURE: 90C
VOLTAGE: 600 V
Payment Terms: | T/T in advance |
---|---|
Qingdao Cable Co., Ltd | |
---|---|
Country/Region: | Shan Dong - China |
Business Nature: | Manufacturer |
Phone: | 13589336354 |
Contact: | Richard Xe (Sales) |
Last Online: | 13 Jul, 2022 |