Electrical Specvifications |
|
Model |
APS1000W |
APS1500W |
APS2000W |
APS3000W |
APS4000W |
APS5000W |
APS6000W |
Inverter Output |
Continuous Output Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
6000W |
Surge Rating(20s) |
3000W |
4500W |
6000W |
9000W |
12000W |
15000W |
18000W |
Output Waveform |
Pure Sine wave/Same as input(Bypass mode) |
Nominal Efficiency |
>88%(Peak) |
Line Mode Efficiency |
>95% |
Power Factor |
0.9-1.0 |
Nominal Output Voltage rms |
100-110-120Vac / 220-230-240Vac |
Output Voltage Regulation |
±10% RMS |
Output Frequency |
50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Short Circuit Protection |
Yes( 10s after fault ) |
Typical transfer Time |
10ms(Max) |
THD |
< 10% |
DC Input |
Nominal Input Voltage |
12.0Vdc |
( *2 for 24Vdc, *4 for 48Vdc) |
Minimum Start Voltage |
10.0Vdc |
Low Battery Alarm |
10.5Vdc / 11.0Vdc |
Low Battery Trip |
10.0Vdc / 10.5Vdc |
High Voltage Alarm |
16.0Vdc |
Low Battery voltage recover |
15.5Vdc |
Idle Consumption-Search Mode |
< 25 W when Power Saver On |
Charger |
Output Voltage |
Depends on battery type |
Charger Breaker Rating |
10A |
15A |
20A |
20A |
20A |
30A |
30A |
Max Charge Rate |
35A / 70A |
Battery Initial Voltage for Start Up |
10-15.7V for 12V( *2 for 24V, *4 for 48V) |
Over Charge Protection Shutdown |
15.7V for 12V (*2 for 24V, *4 for 48V) |
Charger curve(4 stage constant current)
4 step digital controlled progressive charge |
Battery types ( *2 for 24Vdc, *4 for 48Vdc) |
Remote Control |
Yes. Optional |
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) |
Nominal Voltage |
110Vac |
120Vac |
220Vac |
230Vac |
240Vac |
Max Input AC Voltage |
150VAC |
270VAC |
Nominal Input Frequency |
50Hz or 60Hz (Auto detect) |
Low Freq Trip |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz |
High Freq Trip |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz |
Overload protection(SMPS load) |
Circuit breaker |
Output Short circuit protection |
Circuit breaker |
Bypass breaker rating |
10A |
15A |
20A |
30A |
30A |
40A |
40A |
Transfer switch rating |
30amp for UL & TUV |
40amp for UL |
Bypass without battery connected |
Yes |
Max bypass current |
30amp |
40amp |
Bypass over load current |
35amp: Alarm |
45amp: Alarm |
AVR Function |
Input AC Voltage Range |
90-140V±4% |
154-253V±4% |
Stabilized Output Voltage rms |
120VAC±10% rms |
230VAC±10% rms |
Nominal Voltage |
110Vac |
120Vac |
220Vac |
230Vac |
240Vac |
(A) Line Low loss N/W (On Battery) |
84/72 |
92/78 |
168/143 |
176/150 |
183/156 |
(B) Line Low comeback N/W (On Boost) |
89/77 |
97/83 |
178/153 |
186/160 |
193/166 |
(C) Line 2nd boost threshold (On Boost) |
** |
** |
** |
** |
** |
(D) Line 2nd boost comeback (On Boost) |
** |
** |
** |
** |
** |
(E) Line 1st boost threshold (On Boost) |
99 |
108 |
198 |
207 |
216 |
(F) Line 1st boost comeback (On Normal) |
103 |
112 |
205 |
215 |
225 |
(G) Line buck comeback (On Normal) |
118 |
128 |
235 |
246 |
256 |
(H) Line buck threshold (On Buck) |
121 |
132 |
242 |
253 |
264 |
(I) Line high comeback (On Buck) |
127 |
139 |
253 |
266 |
278 |
(J) Line high loss (On Battery) |
132 |
144 |
263 |
276 |
288 |
Mechanical Specifications |
Mounting |
Wall mount |
Inverter Dimensions(L*W*H) |
382*218*179mm |
|
442*218*179mm |
598*218*179mm |
Inverter Weight |
18KG |
|
20KG |
24KG |
35KG |
45KG |
45KG |
Shipping Dimensions(L*W*H) |
520*315*300mm |
|
|