Vibrometer

Vibrometer
Model:XA90-BZ2112C
Brand:-
Origin:-
Category:Electronics & Electricity / Electronic Instrument / Other Electronic Instrument
Label:Vibrometer
Price: -
Min. Order:-
Inquire Now
点击这里给我发消息

Product Description

Vibration Meter
Broadband applications and features suitable for large values of measurements, such as large low-frequency displacement measurement. With the maximum peak, maximum RMS to keep functions such as multi-point burst in the maximum peak and maximum intensity values. To external filters.
1, with the state statutes limited Measuring Instruments charge amplifier all the features and indicators.
2, sub-points: an effective solution of the integral circuit frequency response of narrow, easily susceptible to interference and saturation drift cover disease.
Integral characteristics of the circuit is: Compared with the linear, high-frequency attenuation of low frequency amplification.
3, not only can measure vibration and shock signals positive peak, negative peak, RMS and be permanently maintained, and can measure the range of sizes ranging from vibration and shock signals to maintain the maximum and be permanent.
4, True RMS Measurement: True RMS measurement date used by the U.S. Circuit accurate, stable and reliable.
5, intensity measurement: measurement results meet the ISO2954
6, external filter
7, AC220V and DC12V two kinds of power supply, integrated circuit technology, portable structure (smaller than similar products in 1 / 2), dust shock, both in the laboratory, especially for the field and on-site.
8, three semi-LED display digital panel meters, accurate and clear.
Technical indicators
1, charge amplifier:
(1) input charge range :10-1 ~ 105pC
(2) low-pass frequency limit: 0.1,1,3,10,100 kHz five-speed
(3) low-pass attenuation:-12dB / octave (oct) (order)
(4) Gain: 100,10,1,0.1 fourth gear (amplifiers corresponding piezoelectric magnification: 1,10,100,1000)
(5) sensor suitable for transfer sensitivity: 10 ~ 100pC/Unit
(6) over the Netherlands:> 10Vp
(7) integral curves and linear curves intersect: 1.6,5.06,16,50.6,160 Hz total of five points.
(8) harmonic distortion: <1%
(9) Noise: <15μV (equivalent to the input)
(10) Frequency Response: linear (acceleration): 0.3 ~ 100KHz
Time points (speed): 0.3 ~ 100KHz
Second integral (displacement): 0.3 ~ 10KHz
(11) Accuracy: Linearity: <1%
Time points: <3%
Second Integral: <5%
2, peak table:
(1) Range: 0.01 ~ 10Vp
(2) Input impedance: 100kΩ
(3) Frequency: Continuous signals DC ~ 30kHz (-3dB bandwidth) to respond to a single peak front ≥ 20μs
(4) precision: the peak ± 2% ± 0.1% full scale values: <0.5%
(5) shows: three and a half LED Digital Panel Meters
(6) Measurement options: positive peak, negative peak, rms, no matter which measurement values can be automatically and permanently maintain a series of sample values of the maximum.
(7) Sampling time: 1 second; infinitely long (permanently maintained)
(8) complex zero: Manual; Automatic
3, power supply: AC220V ± 10% DC9 ~ 16V 0.5A
4, Working temperature: -10 ℃ ~ +40 ℃
5, the Working humidity: <85%
6, volume: 235 × 135 × 80mm3
7, Weight: 1kg
Vibrometer 1

Member Information

Midwest Group
Country/Region:Beijing - China
Business Nature:Manufacturer
Phone:15011236554
Contact:Mario C. (Head of Foreign Sale)
Last Online:08 Jul, 2013