1. Classify:X2
2.Application:are suitably used inconnected across a power line、bypass、coupling and switching surge suppressor and other electronic and electrical equipment
3. Features: High insulation resistance, long life due to self-healing effect.
Low loss at high frequency, suitable for high current.
4. General technical data:
u Normative references: GB/T 14472-1998(IEC60384-14 2005)
u Temperature range: 40/110/21
u Rated Voltage: 275VAC(50~60 HZ)
u Capacitance Range: 0.001uF ~ 1.0 uF
u Capacitance Tolerance: ±10%(K)、±20%(M)
u Voltage Proof:1200VDC Of Rated Voltage, 1~5sec. (Between Terminals)
2000VAC, 1~5sec. Between terminal and Enclosure
u Insulation Resistance: CR ≤ 0.33uF IR ≥ 15,000MΩ
CR > 0.33uF IR≥5,000 .S
u Dissipation Factor:<0.1%
5. Construction
u Dielectric: Metalized polypropylene film
u Electrode: Tin zinc
u Lead wire: Tin-plating of copper cover steel
u Coating: Epoxy resin