(1) Discharged gasoline volume: >50 L/min(Heavy Duty:5~85 L/min).
(2) Accuracy: ±0.3%
(3) Pumping distance: 4m
(4) Working Ambient:
1) Adapt temperature: -30℃~ +70℃
2) Relative humidity: <95%
3) Air pressure: 86~106kpa
(5) Power Supply:
1)Voltage: AC220V±20% □
AC380V±20% □
2) Frequency: (50/ 60)Hz
(6) The digits number displayed on display screen:
1) Liter district: 6 digits
2)Amount district: 6 digits
3)Unit price district: 4 digits
(7) Unit price setting range:
0.00~999.9 basic currency(e.g. $) / liter
(8) Counting range for one refueling:
1) Volume: (0.00—9999.99) liters
2) Amount: $(0.00—99999.9)
(10) Counting range for preset filling quantity
1) Preset volume: (0.50—9999.99) liters
2) Preset amount
① If unit price is $ (0.00~9.99)/liter, then
Preset amount: $(0.00—9999.99)
② If unit price is more than $10.00/liter, then
Preset amount: $(0.0—99999)
(11) Counting range of accumulative totals:
Volume: (0.00—99999999.99) liters
Amount: $(0.00—9999999999.99)
(12) Counting range of shift accumulative totals:
Volume: (0.00—99999999.99)liters
Amount: $(0.00—9999999999.99)
(13) Leaves the communication port, so it can communicate with the gas station management system.
(14) All important data shall be kept for ten year in case of power failure.