Model: | HTQF |
---|---|
Brand: | HOTEAM |
Origin: | Made In China |
Category: | Electronics & Electricity / Power Supply & Distribution / Other Power Supply & Distribution |
Label: | active power filter , activeharmonicfilter , RC filter |
Price: |
-
|
Min. Order: | 1 sey |
Harmonic Filter: HTQF is composed of command current computing circuit and compensation current generating circuit. Command current computing circuit conducts real-time monitoring of current in circuit; switch the analogue current signals into digital signals, and send the signals into DSP for handling; separate harmonics and fundamental wave, send drive pulse in form of PWM signals to compensation current generating circuit; drive IGBT power module, produce compensation current input network which has the same amplitude as harmonic amplitude and inverse polarity; compensate or balance out harmonic current, eliminate power harmonics actively, and thus realize the dynamic quick and complement treatment of power harmonics.
Dynamic reactive power compensation: While filtering harmonics, according to detected need for reactive power compensation, HTQF command current computing circuit can control internal capacitive and inductive fundamental current of compensation current generating circuit, conduct real-time compensation, set the target value of reactive power compensation through operation board. There are 4 working modes for choice, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “and reactive power compensation only”. The working mode should be selected according to specific conditions of power distribution system.
Correct unbalanced 3 phases: HTQF can compensate the unbalanced 3 phases respectively. It can conduct phase adjustment of active power through DC Energy Storage Systems shared by 3 phases, thus to correct unbalanced load of 3 phases. The operation of this function can also be set by operation board.
HTQF technical parameters
model |
HTQF/3L-0.4/xxA 3P3L |
HTQF/4L-0.4/xxA 3P4L |
feature |
||
|
Apply to 3P3L system |
Apply to 3P4L system, can realize netral line filter |
Compensation current of each cabinet |
50A |
50A |
75A |
75A |
|
100A |
100A |
|
150A |
150A |
|
200A |
200A |
|
250A |
250A |
|
300A |
300A |
|
400A |
400A |
|
500A |
500A |
|
600A |
|
|
input |
||
voltage |
400/600V -15/+10% |
400/600V -15+10% |
frequency |
50/60HZ ±5% |
50/60HZ ±5% |
Performance index |
||
Filter capacity |
Can be more than 97% |
Can be more than 97% |
Filter range |
2~50th harmonic |
2~50th harmonic |
Response time |
Transient response<0.1ms, complete response<20ms |
Transient response<0.1ms, complete response<20ms |
Neutral line compensate ability |
---- |
3 times in line RMS current |
Reactive power compensation |
Setting range of power factor is from inductive0.6 to capacitive 0.6 |
Setting range of power factor is from inductive0.6 to capacitive 0.6 |
Balance compensation |
Programmable balance of power |
Programmable balance power of phase and phase or phase and neutral line |
Overload protection |
Automatic current limiting when 100% rating output |
Automatic current limiting when 100% rating output |
Power loss |
≤3% rated compensation capacity |
≤3% rated compensation capacity |
CT requirements |
3set, 0.2magnitude or more,secondary 5A |
3set, 0.2magnitude or more,secondary 5A |
Current detection means |
Source current detection or load current detection |
Source current detection or load current detection |
Display and interface |
||
language |
English/Chinese |
English/Chinese |
Operating button |
Start/stop、reset、menu、confirm、fluctuation function keys and so on |
Start/stop、reset、menu、confirm、fluctuation function keys and so on |
Indicator light |
Green: normal operation |
Green: normal operation |
Orange: overcurrent/overload operation |
Orange: overcurrent/overload operation |
|
Red: machine halt or alarm |
Red: machine halt or alarm |
|
Communication interface |
RS-485 |
RS-485 |
Communication protocol |
MODBUS(RTU) |
MODBUS(RTU) |
digitI/O |
4 digital input, 2 digital alarm |
4 digital input, 2 digital alarm |
configuration |
||
Unit operation |
allow |
allow |
Parallel operation |
10 sets at most |
10 sets at most |
IP |
IP3X,(higher IP pls contact manufactuer) |
IP3X,(higher IP pls contact manufactuer) |
Color |
RAL7035(light gray), can be customized according to use requirements |
RAL7035(light gray), can be customized according to use requirements |
Environment condition |
||
temperature |
-10~40℃ |
-10~40℃ |
Storage temperature |
-25~55℃ |
-25~55℃ |
Relative humidity |
Max 95%RH(no condensation) |
Max 95%RH(no condensation) |
altitude |
1000m |
1000m |