4,Three standard plating(copper sulfate,nickel 8-12mu and chrome 0.2-0.3mu)
Technical datas:
Working pressure |
0.05-1Mpa |
Ideal working pressure |
0.1-0.5Mpa |
Cold water temp range |
5-29°C |
Hot water temp rang |
50-80°C |
Outlet temp range |
20-50°C |
Set security button temperature |
38°C |
Cold water test |
running cold water five seconds,flow rate dropped to 1.9L per minute,water out ≤150ML, leaving water temp≤49°C |
Lifespan test |
CSA B125-98 ASSE 1016(≥100,000cycle) |
Water temperature automatically regulate sensitivity |
as the temperature and pressure variation 20%,water temperature changes≤2°C.as the pressure constant,the temperature change of hot water 50-80°C, cold temperature 4-29°C, and the water out temperature≤2°C |
Standards |
CSA B125-98 ASSE 1016 EN 1111 AS-4032 |
Guarantee period: 3years
Sample t ime: 3days at factory.
Bulk production time: 4-5 days
SKYPE: krista025
WEB: www.zilantech.com