Humidity: |
5% to 95% RH (non-condensing) |
EMI/RFI: |
Complies with EMC Directive 89/336/EEC |
|
|
Ingress protection: |
IP 66/67 |
Battery: |
Lithium, non-replaceable |
Continuously on: |
Yes |
One-button control: |
Activation, self-test and alarm event data transmission |
Full functional self-test: |
Verifies integrity of sensor, circuitry, battery and audible/visual alarms |
Sensor: |
Electrochemical cell (temperature compensated) |
Operational life: |
Three years |
INDICATORS AND ALARMS: |
Visual alarm: |
Flashing, wide-angled alarm lens with red quad-LEDs, plus fl ashing ALARM icon |
Audible alarm: |
Pulsing, high-output siren at 95 dB (typical) at 1 ft. (0.3 m) |
Vibrator alarm: |
Internal |
Failure alarm: |
Yes (audible/visual/vibration) |
Self-test pass: |
Yes (audible/visual/vibration) |
Other: |
End-of-life (audible/visual/vibration) |
CONTINUOUS LCD DISPLAY: |
Status display |
Life remaining: |
Continuously displayed in months, then days, then hours |
Two alarm levels: |
LOW alarm / HIGH alarm |
Peak alarm exposure: |
Records and displays peak alarm exposure, and time elapsed (up to 24 hrs.) |
Alarm setpoints: |
High and low (displayed on demand in ppm) |
Self-test status: |
Advises to "TEST" and that self-test was passed "u" |
TESTS: |
Full function self-test: |
On activation and on demand |
Battery: |
Every two hours (auto) |
EVENT LOGGING: |
Records and transmits up to 10 gas alarm events |
Event information: |
Gas type, peak exposure level (ppm or %); alarm duration in minutes and seconds; time elapsed since the alarm occurred in days, hours and minutes, life remaining, serial number, self-tests, cumulative alarm time |
Transmission method: |
Via infrared port to infrared printer or to an IR DataLink |
PHYSICAL SIZE: |
Size: |
1.1 x 2.0 x 3.2 inches / 28 x 50 x 81 mm |
Weight: |
2.7 oz. / 76 g |