Model: | SDH-60 |
---|---|
Brand: | ASLi |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | temperature humidity , environmental chambe , thermal shock |
Price: |
US $10000
/ set
|
Min. Order: | 1 set |
Sulfur Dioxide Salt Spray Chamber Application:
Sulfur Dioxide salt spray chamber are widely applied to the accelerated corrosive testing of the protective layer from metallic materials, as well as parts ,
electrical components and industrial products. It can reproduce the corrosionprocess happened to the painted or untreated metal surface. Therefore it can be used
to perform various kinds of corrosion test in according to relevant standards, such as ISO6988-1985.
Sulfur Dioxide Salt Spray Chamber Features:
Anti-corrosive CPVC plate is formed integrally through pressing and with no leakage.The space between tank lid and tank body is water sealed with no air leaking.
While the lid, which is made of transparent material, allows you to observe the testing items inside clearly to know the status. It has been equipped with double air
filter ensure that the emission gas brings no contamination to environment. Wired control board and other electrical components are positioned in certain places for
easy check and maintain.
Pls feel free to contact us for detail specifications.
Rachel@aslitesting.com
(Ms.Rachel Lee)
Tel.:0086-769-23164266
Cell:0086-13602387384
Skype:asli168
www.aslitesting.com
Sulfur Dioxide Salt Spray ChamberTechnical Parameters:
Model |
SDH-60 |
SDH-90 |
SDH-120 |
||
Internal Dimension
|
600x450x400 |
900x600x500 |
1200x800x500 |
||
External Dimension
|
1100x600x1200 |
1400x950x1200 |
1900x1300x1400 |
||
Lab Temperature |
Saline test (NSS ACSS): 35±1 ℃ ; Corrosion Test (CASS): 50±1 ℃ |
||||
Pressure Bucket
|
Saline test method (NSS ACSS): 47±1 ℃; Corrosion Test (CASS): 63±1 ℃ |
||||
Lab Capacity (L) |
110 |
270 |
500 |
||
Saline Capacity (L) |
15 |
25 |
40 |
||
Salt concentration |
5% concentration of NaCl, or every Liter 5% NaCl add 0.26g CuCl2H2O |
||||
Compressed Air
|
1.0~6.0 |
||||
Spray Volume |
1.0~2.0ml /80cm2 /h(working at least 16 hours, and take the average value) |
||||
Spray Form |
Continuous Spraying or Programmable Spraying |
||||
Gas Density |
0.1~1% adjustable |
||||
Gas Generated |
Titration/cylinder Method |
||||
Power |
AC220V, 1∮3 lines, 15A |
AC220V, 1∮3 lines, 15A |
AC220V, 1∮3 lines, 15A |
Ai Si Li (CHINA) TEST EQUIPMENT CO., LTD) | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 13826932967 |
Contact: | Joanna Wen (Sales Manager) |
Last Online: | 28 May, 2018 |