PVC roof waterproof membrane

PVC roof waterproof membrane
Model:PVC
Brand:Dayu
Origin:Made In China
Category:Construction & Decoration / Waterproof Materials
Label:pvc roof felt , UV-resistance felt , roof membrane
Price: US $2.2 / sqm
Min. Order:1000 sqm
Inquire Now

Product Description

Detailed Product Description

 
manufacturer of membrane with high quality and the best price
CE,ASTM Standarded
thickness:1.0mm~2.0mm
roll size:41sqm/roll

 

Product description

 

Features

1.High Tensile strength, excellent resistance to tear and puncture.

2.Strong adhesion with the concrete, effectively prevent the emergence of a single polymer sheet phenomenon of channeling water.

3.Lap with pre- self-adhesive side lap to ensure the seamless of waterproof system.

4.Perfect resistance to acid&alkali,weather and aging.

5.Simple operation, High work efficiency, Low cost.

6.Non toxic, tasteless and be environmentfriendly.

  

Scope of Application

  1. Large-scale underground structures.
  2. Surface of concrete slabs for planting.
  3. For Roads, Rails, Subway tunnels projects.
  4. For reservoirs, canals, dams and other water conservancy projects.
  5. For air defense, military facilities waterproof projects. 

Construction technology

  1. Tunnels, bridges should use polmer sheet welding lap joints. Firstly, pre-paved polymer sheet side of polymer self-adhesive composite waterproof membrane toward the base, and fix it with dedicated pieces of machine, double lap weld seam welding machine should be used for lap joints. Tear off insulation paper, band reinforced concrete directly, self-adhesive waterproof membrane will adhere to the main body of concrete structure closely to achieve full adhesion.
  2. General building underground projects should use self-adhesive overlap method. Basement bottom: pre-laying the membrane on cushion firstly(polymer sheet face down), tear off reserved isolation paper of lap joints self-adhesive side and can be sealed when paste directly; tear off isolation paper of self-adhesive waterproof layer, structural concrete, the membrane will anti-stick to the concrete structure to form dense waterproof system.
  3. Basement side wall, Surface of concrete slabs for planting: attach the self-adhesive material side to the base surface directly, tear off reserved isolation paper of lap joints self-adhesive side. Side wall shall be fixed with dedicated pieces of machine.
  4. Half header treatment:Wether horizontal half header or vertical half header, which should be sealed with sealant, membrane in the elevation without groove half header, it shall be fixed with metal straps firstly, then seal the top hole of metal straps and fixed screw with sealant.

Cautions

  1. Do not put the membrane on a pollution, water and ice ground.
  2. Construcion of waterproof layer operations can't be crossed, device shall be installed on the waterproof layer, parts should be done to strengthen the basis of device and to take protective measures.
  3. Do not touch the waterproof layer with thorn sharp objects after it's has been completed, don't put sundries or any additional buildings above the waterproof layer to avoid damaging it.

Storage and Transportation

Be under the dry and well-ventilated condition; avoid sunlight and raining.

Stand straightly; lay flat and be packed in the same direction without no more than 5 layers.

Shelf life: One year.

 

Technical data sheet:

 

Guangdong Province Contruction Products Inspection Center

Test Report

 

 

 

 

Consigners:GuangzhouDayu waterproof Co,Ltd.

Ref No:GD2010-01-00134

Sample name:DY-PVC Waterproof Membrane

Sample No:010-01-00134

Specifation/modle: NI 1.5(I)

Sample quanity:1M2

Factory:Dayu waterproof Co,.Ltd

Test date:5-1-2010

Ref Standards:GB12952-2003

Report date:19-2-2010

 

 

 

 

No.

Test Item

Standard Value

Measured value

1

Tensile strength,Mpa

≥8.0

8.73

2

Enlongationat break, %

≥200

236

3

Anti-penetration resistance

0.3Mpa in 2 h,          No leakage

No Leakage

4

Cold flexible

-20°C,No cracking

No cracks

5

Adhesivity in shear conditon, N/mm

≥3.0

3.27

Conclusion

All test are qualited based on the Ref Standards:GB12952-2003 's conventional items and instruction .

PVC roof waterproof membrane 1PVC roof waterproof membrane 2PVC roof waterproof membrane 3PVC roof waterproof membrane 4

Member Information

Guangzhou Dayu Waterproof Co., Ltd.
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:15018766306
Contact:David Yu (sales manager)
Last Online:06 Nov, 2013