Model: | SKU:ST-2500 |
---|---|
Brand: | SG |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | inverter |
Price: |
-
|
Min. Order: | 1 pc |
The parallel quantities in one system can be composed freely in the range of 10PCS, so you can
Stack 2 for 5,000W Continuous Max Power
Stack 3 for 7,500W Continuous Max Power
Stack 4 for 10,000W Continuous Max Power
Stack 5 for 12,500W Continuous Max. Power
Applying to electric appliances:
To ensure proper efficiency the total load should not exceed 90% of the inverters continuous output power, and the start power of the load should not exceed the output surge power of inverter.
There is an intelligent protection system with audio and visual alarms, ST dc to ac converter feature a full range of protection including; over-voltage protection, low-voltage alarm, under-voltage protection, over-heating protection, overload protection, short circuit protection, reverse polarity protection etc.
Installation Connections:
1. The Master/Slave switch MUST be set to MASTER. If the selection switch is set to the slave position, there will be no power output.
2. The positive and negative terminals on the inverter must be hooked to their respective positive and negative terminals on the battery. The larger the system the thicker the wires need to be. Use only appropriately rated fuse blocks or breakers inline with the positive cable. If you cannot feed the inverter with enough input power, then the output will be low or no output.
3. Switch on the dc ac converter. If the LED indicator is green, it means the inverter is working properly. If the LED is red and you hear a beep, this means that the DC input voltage low or incorrect. Immediately turn off the inverter and check your connections.
4.Plug your appliance into the inverter, then switch the inverter on. A green light indicates that everything is working as it should. The inverter has soft-start function.
5.When in use if the alarm beeps the LED indicator will turn red, which means the inverter went into protection mode. Protection mode is an automatic shut down to help avoid damage from happening to the inverter. The number of beeps corresponds to a fault code, these inverters are smart as they tell you what is wrong. You can check the fault code in the “Protection Features” section below.
Specification :
Model |
ST-2500 |
|||||||||
AC Voltage |
220V/230V/240V |
100V/110V/120V |
||||||||
Continuous Power |
2500W |
|||||||||
Output Surge Power |
5000W |
|||||||||
Converting Efficiency |
>88% |
>90% |
>92% |
>88% |
>90% |
>92% |
||||
Normal Input Voltage |
DC12V |
DC24V |
DC48V |
DC12V |
DC24V |
DC48V |
||||
Input Voltage Range |
10~15V |
20~30V |
40~60V |
10~15V |
20~30V |
40~60V |
||||
Output Voltage |
AC220V/230V/240V±5% |
AC100V/110V/120V±5% |
||||||||
Output Frequency |
50Hz |
60Hz |
||||||||
Output Wave Form |
Modified Sine Wave |
|||||||||
No load Current |
<0.15A |
<0.12A |
<0.12A |
<0.15A |
<0.12A |
<0.12A |
||||
Input Low Voltage Alarm |
10.5±0.5V |
21±0.5V |
42±1V |
10.5±0.5V |
21±0.5V |
42±1V |
||||
Input Under Voltage Cut Off |
10±0.5V |
20±0.5V |
40±1V |
10±0.5V |
20±0.5V |
40±1V |
||||
Input Over voltageCut Off |
15±0.5V |
30±0.5V |
60±1V |
15±0.5V |
30±0.5V |
60±1V |
Working environment :
1. Operation temperature: -10℃~40℃.
2. Storage temperature: -40℃~85℃.
3. Considerable air humidity should be less than 85%.
4. No electrical conductivity, dust explosion, corrosion-free gas in the working place.
5. No shock and vibration in the working place.
Physical properties:
A. G.W.:8.5kgs
B. Size: 420 mm *255 mm *100 mm
Sun gold power co.,ltd | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 89330906 |
Contact: | Summer (sales) |
Last Online: | 16 Jan, 2014 |