Model: | ETCR8000 |
---|---|
Brand: | ETCR |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | - |
Price: |
-
|
Min. Order: | - |
ETCR8000 Leakage Current Monitoring Recorder is designed and manufactured for field online testing, monitoring, AC current leakage and current record; it is composed of the host, ETCR leakage current monitoring software, current clamp and communication lines, etc. It is widely used in electric power, telecommunications, meteorology, railways, oil field, construction, measurement, research and teaching units, industrial and mining enterprises, etc.
The host is in clear blue LCD display, with large storage space, can store 4,200 sets of data; it also has automatic storage interval time setting from 1 to 60 minutes.
ETCR8000 Leakage Current Monitoring software has online real-time monitoring and historical query function, in dynamic display, wave indication, with maximum, minimum and mean value indication, alarm settings and alarm indicator functions, historical data reading, access, storage, analysis, processing, sorting, sequence, fitting curve, report and printing, etc.
Special alloy is used for current clamp; apply the latest CT technology and magnetic shielding technology, almost free of the influence of external magnetic field, ensuring continuous monitoring of year-round high accuracy, high stability and high reliability.
ETCR8000 Leakage Current Monitoring Recorder is applicable to AC line below AC600V, can start accurate testing from 0.01mA; quite accurate in finding insulation failure, circuit with insulation failure, monitoring intermittent leakage fault; viewing the time of insulation failure occurrence and line maintenance.
Ⅱ. Technical Specifications
Functions | Measuring AC leakage current and AC current, monitoring current in real-time manner, locating insulation faults and repairing electrical lines. |
Power source | DC6V, alkaline battery LR6 1.5V×4 |
Testing Method | |
Range | |
Resolution | |
Accuracy | ±2%±5dgt |
Clamp size | |
Instrument Dimension | Tester(L×W×H): Current clamp(L×W×H): |
Mass | Tester: Current clamp: |
LCD Dimension | Display field: |
Shield Type | Type B: Double shielding |
Sampling Rate | 2 samples/s |
Data storage | 4200 sets (data loss does not occur after power failure or replacing the battery) |
Time Setting | Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off |
Recording Time | Continuously operate for about 10 days at the power-saving mode |
Line Voltage | Line with a voltage up to AC600V |
Overflow Display | The “OL” symbol is displayed when a measured value is beyond the measurement range |
A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. | |
Rated Power | about 5mA at the power-saving mode, maximum current consumption: 20mA |
Lead Length | |
Temperature and Humidity | Working: |
Storage: | |
Insulation Resistance | Higher than 100MΩ, 1000V |
Safety Codes | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Tester: 1 PCS, Current clamp: 1 PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS |
Guangzhou ETCR Electronic Technology Co., Ltd. | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 62199554 |
Contact: | James Vu (Sales Assistant) |
Last Online: | 15 Jul, 2013 |