The original quality goods OMRON E2E2 X18MY2 -- M4

The original quality goods OMRON E2E2 X18MY2 -- M4
Model:E2E2-X18MY2-M4
Brand:omron
Origin:Made In Japan
Category:Electronics & Electricity / Electronics Stocks
Label:e2e2 , omron , E2E2-X18MY2-M4
Price: ¥209 / pc
Min. Order:1 pc
Inquire Now

Product Description

Rated specifications/performance Dc line 2 (E2E2 - / X/D) Size M12M18M30 Shield shield not shielding shielding shielding screen the screen Project model E2E2 - X3D/E2E2 - X8MD/E2E2 - X7D/E2E2 - X14MD/E2E2 - X10D/E2E2 - X20MD - Detection distance of 3 mm + / - 10% in 8 mm + / - 7 mm to 14 mm + / - 10% + 10% to 10% 10 mm + / - 10% 20 mm + / - 10% Set distance 2.4 mm0 ~ 6.4 * 10 ~ 5.6 mm0 mm0 ~ ~ 11.2 mm0 mm0 ~ 8 ~ 16 mm Should be differential detection distance is less than 10% Magnetic metal detection objects (non-magnetic metal detection distance shorter. Please see ➜ the Catalog of "feature data" Standard testing objects iron 12 * 12 * 1 mm iron 30 * 30 * 1 mm iron 18 x 18 x 1 mm iron 30 * 30 * 30 * 30 * 1 mm iron 1 mm iron 54 * 54 * 1 mm * 21 khz800hz500hz400hz100hz response frequencyPower supply voltage (using the voltage range) DC12 ~ 24 v ripple (p - p) below 10% (DC10 ~ 30 v) Leakage current 0.8 mA Control the output switch capacity of 3 ~ 100 ma Residual voltage 3 v the following (when load current is 100 ma, cable 2 m long) Lamp type D1: action (red), set to display (green) D2: action show (red) Mode of action (close to the test object) D1 type: NO D2: NC For details, please see ➜ the Catalog of "input and output circuit diagram" sequence diagram Surge protection circuit of absorption, load short circuit protection When environment temperature work, save: each - 25 ~ + 70 ℃ (without freezing and condensation) Environmental humidity, save: when each 35 ~ 95% RH (no condensation)The influence of the temperature of 25 ~ + 70 ℃ temperature range, + 23 ℃, the detection distance of plus or minus 10% Voltage influence of plus or minus 15% of the rated supply voltage range, rated supply voltage, detecting distance within plus or minus 1% Insulation resistance more than 50 m Ω (DC500V megger) charging department between the shell and as a whole AC1, withstand voltage 000 v 50/60 hz 1 min charge between whole and shell Vibration (durability) 10 ~ 55 hz fluctuation amplitude is 1.5 mm 2 h X, Y, Z direction Impact (durable) 1000 m/s2 X, Y, Z direction 10 times each IEC standard IP67 protection structure, internal standard oil resistant Connection wire draw out type (standard cable 2 m long) Quality (after packing) about 65 g, 150 g, 210 g Brass surface Test surface poly butyl glycol terephthalate (PBT) Tighten nut brass, nickel plated Toothed washer, galvanized iron Attachment specification

* 1. Please use within the scope of the green indicator lights. Except type (D2) * 2. The average frequency for response of dc switch department. Measurement conditions: using the standard test object, test interval for the standard inspection object 2 times, setting distance to 1/2 of the distance.

Payment Terms:TT
The original quality goods OMRON E2E2 X18MY2 -- M4 1The original quality goods OMRON E2E2 X18MY2 -- M4 2The original quality goods OMRON E2E2 X18MY2 -- M4 3

Member Information

Senmeirui Technology Co.,LTD
Country/Region:Guang Dong - China
Business Nature:Trading Company
Phone:18902436749