 Model NO.: GMF-MP-700

Type: Patient/Fetal/Maternal Monitor

Main Features:

1, 12.1 inch high resolution color TFT display.

2, 96 hours trend graphic data, 12-lead ECG analysis.

3, Arrhythmia and S-T segment analysis.

4, Anti-defibrillation, Anti-high frequency electrotome.

5, Multi-language, easy operate, durable and stable.

6, Calculation function of drug concentration, drug titration and

Hemodynamic status.

7, Wired or wireless network.

8, Three-level Audible and visible alarm, events recallable Nurse Call function.

9, AC/DC power supply, built-in high capacity battery.

Standard configuration:

ECG, RESP, NIBP, SPO2, PR, TEMP

 

Optional function:

IBP, EtCO2, Cardiac output, Printer

 

Specification:

Dimension: 272(H) X 327(W) X 145(D) mm

Weight: 6.5 Kgs ( with battery)

 

ECG

Measuring range: Adult 0~300bpm

Neonate and pediatric 0~350bpm

Band width: 0.05Hz~100Hz

Accuracy: ± 1%

Lead Type: 5-lead and 3-lead selectable

Lead selection: Standard I, II, III; Augmented limb lead

AVR, aVL, aVF; Chest lead V 1~V6

Resolution: 1 bpm

Trend monitoring time: No less than 96 hours

ST-Segment analysis: -2.0 mV ~2.0mV; Auto

Arrhythmia analysis: 13 kinds of Arrhythmia analysis

Scanning speed: 12.5, 25, 50mm/Second

Gain selection: X1/2, x1, x2; Auto

Protection: Withstand 4000 VAC/ 50Hz voltag e

Voltage in isolation against

Defibrillation and electrosurgical

Interference

ECG cable: Adults, pediatric and neonate

Alarm Range: 15-350 bpm

ARR Alarm: Audible and visible alarm,

Events recallable

 

NIBP

Method: Automatic Oscillometric

Operation Model: Manual, automatic, continuous

Auto measurement

Time interval: Adjustable 1 /2 /3/4

/5/10/15/30/60/90/120/240/480 Min.

Measuring Unit: MmHg /kPa selectable

Measurement types: Systolic, Diastolic, Mean

Measuring Range: Adult: 10~270 mmHg

Pediatric: 10~200mmHg

Neonate: 10 135mmHg

Cuff pressure range: 0~320mmHg

Cuff type: Adult cuff (standard)

Pediatric and Neonate(Optional)

Neonate  

Cuff inflation time: < 10 seconds

Cuff deflation time: <20 seconds

Over-Pressure

Protection: Yes

Alarm: Upper alarm, lower alarm, Auto-memory

 

SpO2

Measuring range 0~100%

Resolution: 1%

Accuracy: ± 1% ( 70%~100%)

2% (0%~69% )

PR measuring range: 0~255 bpm

PR accuracy: ± 1 bpm

Sensor Type: Adult sensor (standard)

Pediatric sensor

Neonate sensor

Alarm Range: 0~100%

 

RESP

Display: Waveform display and numeric display

Operation Mode: Auto/Manual

Method: Trans-thoracic impedance

RR Measuring range: 0~150bpm

Accuracy: ± 1 bpm

Apnea alarm threshold: 10s, 15s, 20s(default), 25s, 30s, 40s

Band Width: 0.2-2.5Hz (-3dB)

Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s

Alarm Range: Adult: 6-120rpm

Pediatric and Neonate: 6-150rpm

 

TEMP

Measuring range: 0~ 50G ( 32~122T )

Probe Type: Body temperature probe (standard)

Esophageal temperature probe

Rectal Temperature probe

Resolution: 0.1

Accuracy: 0.1

Channel: Dual-channe, Provide T1, T2

Alarm Range: 0~50

 

IBP (Optional)

Measurement range: - 10 ~ 300 mmHg

Channel: 2 channels

Sensitivity: 5 μ V/V/mmHg

Impedance range 300~3000Ω

Accuracy: ± 1 mmHg or ± 2%

(exclusive of transducer)

Alarm Range: -10 ~ 300 mmHg

EtCO2 (Optional)

Measurement range: 0 ~ 150 mmHg

Accuracy: 1rpm

Sample flowerate: 50 ml/min

Sample rate accuracy ± 15% or 15 ml/min.

Respiration rate: 0 ~ 120 rpm

Respiration accuracy: ± 2 rpm (0 ~70 rpm)

5 rpm (>70 rpm)

Respiration time: < 60 ms

Delay time: <2s