Product Description

schneider inverter

 SWX0X3CADGEBG4CANWBKWTCA7IF1HKCAUYXAD8CAB1EUZ9CA2FHHMXCAT0F9C8CAZDREN6CA2HJ3GCCABJET75CAVDD3VDCAPPJK17CAPUP3XLCAD35OYFCATWQ7DSCA2MTNBLCAQ6QDO0CA0U3WJK.jpg

Main features:

 1. sine wave power inverter

2.12/ 24VDC optional

3.Pure sine wave

4.Low frequency, inbuilt transformer.

5.AVR function

6.Charge current Max.25A.

7. Support inductive load, motor, generator.

8. Input range: 145-275vac

9. output: 230vac+/-10%

10. RS232 available

11. LCD panel

12. transfor time: 5ms

13.protection: automatic self-test, discharge protection, over charging protection, short-circuit protection.low voltage, over voltage,over load,over heating protection etc

 

We sell all series of schneider frequency inverter ,INVERTOR ,HMI at competitive price with big stock.1.1kW-1.5HP - 380-500 - 50

 

Altivar 312

1.1kW-1.5HP - 380-500 - 50/60Hz

ATV312HU11N4

 NVUDRYCA99L6UOCAJ80LN7CA2W8C65CAASKLSACAWOENY3CAW5L8IYCAPO0QCPCAD9J3N1CA3OU83ZCA9HNWTWCAUOUNYJCARKFY18CAML7QUPCADJI5IKCA6LC1L1CAGYDHMZCADBB0KTCABLWDXS.jpg

More Modules:

UL Type 1/IP 20 drives, 1-phase supply voltage 200…240 VAC, 50/60Hz

ATV71H075M3

ATV71HU15M3

ATV71HU22M3

ATV71HU30M3

ATV71HU40M3

ATV71HU55M3

ATV71HU75M3

UL Type 1/IP 20 drives, 3-phase supply voltage 200…240VAC, 50/60Hz

ATV71H037M3

ATV71H075M3

ATV71HU15M3

ATV71HU22M3

ATV71HU30M3

ATV71HU40M3

ATV71HU55M3

ATV71HU75M3

ATV71HD11M3X

ATV71HD15M3X

ATV71HD18M3X

ATV71HD22M3X

ATV71HD30M3X

ATV71HD37M3X

ATV71HD45M3X

ATV71HD55M3X

ATV71HD75M3X

 

 

 

MODEL 115V Models 230V Models
OUTPUT
Power Levels crated at 1000VA /600W;2000VA / 1200W 1KVA /0.6KW;2KVA / 1.2KW
nominal inputs 3000VA / 2250W;5000VA/3500W 3KVA /2KW;5KVA/3.5KW;10KVA/6KW
Output Voltage 100V/110V/115V/120V Selectable 200V/220V/230V/240V Selectable
Voltage Waveform Pure Sine wave
Crest Factor 3:1
Output Frequency Auto Select for 50/60Hz
(Synchronized to Mains) 47Hz ~ 55Hz for 50Hz nominal
56Hz ~ 65Hz for 60Hz nominal
Regulation (Nominal) ±10% typical of nominal voltage
Regulation(Battery mode) ±3% of selected output voltage (adjustable with theremote set-up software)
Transfer time Blackout 3ms typical
Brownout 1ms typical
Battery mode to Normal mode??1ms typical
Over current protection Over load alarm level 100% ~ 120%
Over load shutdown level 120% ~ 190%
(Adjustable by using the remote set-up software)
INPUT
Nominal Voltage 100V/110V/115V/120V Selectable 200V/220V/230V/240V Selectable
Input Frequency 47Hz ~ 65Hz, 50/60Hz auto-sensing
Efficiency (Normal mode) 97%
Noise Filtering Full time EMI/RFI filtering
Over current protection Re-settable over current protector
500VA ~ 5000VA
AC Fuse 1000VA/1500VA
Re-settable over current protector from 1.5KVA to 10KVA
Voltage Range 75V ~ 155V 145V ~ 310V
AVR Range(2 Bucks, 2 Boosts) Enhanced Buck: +28% of selected nominal voltage
Buck mode: +10% of selected nominal voltage
Boost mode: -10% of selected nominal voltage
Enhanced Boost: -25% of selected nominal voltage
Surge Protection 500VA/1500VA 216 Joules
1500VA~5000VA 424 Joules
500VA/1500VA 220 Joules
1500VA~10000VA 834 Joules
BATTERY
Battery type Lead-Acid 50Ah to 500Ah (Recommended) Lead-Acid 50Ah to 500Ah (Recommended)
Voltage 500VA/800VA/1000VA: 12Vdc
1500VA/2000VA:  24Vdc
3000VA/5000VA:  48Vdc
500VA/800VA/1000VA: 12Vdc
1500VA/2000VA: 24Vdc
3000VA/5000VA/10kAV: 96Vdc
Typical backup time No Limit
Charging method Quick charging when battery is not fully charged,
trickle charging when battery is 90% fully charged.
Maximum charging
current
1500VA/15A ;2000VA/20A ; 3000VA/20A ; 5000VA/20A   1500VA/15A ;2000VA/20A ;
3000VA/20A ; 5000VA/20A  
Average charging Quick charging mode:14V maximum.
voltage for each battery Trickle charging mode:13.5V (adjustable with the remote set-up software)
Protection Over current protection & Over charging voltage protection (SCR control)
Thermal protection (CPU control)
When temperature inside the unit is over 45 °C, charger will  stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate
Monitoring Smart monitoring & warning for failed battery or open-circuit battery.
Auto-detection each time when power on or every 6 days.
SOLAR CHARGER(OPTIONAL)
Rating voltage 12V / 24V / 48V 12V/24V/48V/96V
DC input range 12V model : 12 ~ 21Vdc
24V model : 24 ~ 42Vdc
48V model : 48 ~ 84Vdc
Charging method Constant voltage with current limiting by PWM control
Charging voltage 12V model :13.5Vdc
24V model : 27.0Vdc
48V model : 54.0Vdc
Power rating 12V model : 500W (13.5Vdc @ 37A)
24V model : 1000W (27.0Vdc @ 37A)
48V model : 1000W (54Vdc @ 18.5A)
Protection DC input polarity protection, DC input short circuit protection( when battery is