Insertion type Vortex Flow meter

Insertion type Vortex Flow meter
Model:-
Brand:KCCV
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Air & Gas Flowmeter
Label:flow meter , flowmeter , flow instrument
Price: -
Min. Order:10 pc
Inquire Now

Product Description

Feature

1.Apply to pipe size DN150 or above

2.Can output 4-20mA to secondary instrument or some Intelligent Module such as DCS, PLC

3.Can output pulse and equipped with flow totalizer for remote monitoring

4.Can communication with computer or other control system under RS485 or HART protocol

5.Battery-powered or External-powered

 

Main Technical parameters

Fluid Medium

LiquidGasSteamSingle medium or medium can be viewed as single medium,Saturated steam with dryness no less than 85% can be viewed as single medium

Medium Temperature

In-line Type

-40℃~+250℃300℃400℃450℃

Insertion Type

-20℃~+250℃300℃400℃

Working pressure

1.6MPa  2.5MPa  4.0MPa (4.0MPa above need special order)

Accuracy

In-line Type

±0.5%±1.0%±1.5%

Insertion Type

±2.5%

Turndown ratio

8:1   10:1   15:1   20:1

Flow rate

Liquid 0.3~7.0m/s, Gas4.0~60.0m/s, Steam 5.0~70.0m/s

Size

In-line Type

DN25, DN 40, DN 50,  DN 80,  DN 100,  DN 150

DN 200,  DN 250,  DN 300 DN 300 above need special order

Insertion Type

DN200~DN1500DN1500 above need special order

Material

304 stainless steel (Other material need special order )

Vibration acceleration  Permitted

Piezoelectricity  0.2g

Capacitance     1.0g

Enclosure

General  Type: IP65  Submersible  Type: IP68

EEX

(ia) IICT2~T5

Environment Condition

Temperature

Un-explosion-proof: -40℃~+55℃  

Explosion – proof:  -20℃~+55℃

Humidity

≤90%

Atmospheric Pressure

86~106Kpa

Power Supply

Un-explosion-proof

Pulse output:  +24VDC

Current output: +24VDC  4~20mA

Explosion-proof

Pulse output:  +24VDC, +12VDC (with Zener-barrier LB978)

Current output: +24VDC 4~20mA with Zener-barrier LB987S

Output Signal

Frequency pulse signal: 2~3000 HZ  Low level≤1V,  high level ≥5V

2-wire 4~20mA, Explosion-proof : load≤300 Ω  Un-explosion-proof: load≤500Ω

 

Insertion type Vortex Flow meter 1

Member Information

Jiangsu KCCV Co.,LTD
Country/Region:Jiang Su - China
Business Nature:Manufacturer
Phone:15183599
Contact:Renee Wang (Sales Manager)
Last Online:27 Dec, 2013