Features:
1. Audible and visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting etc, which gains patents
2. More Drug library
3. Compatible with 10ml, 20ml, 30ml, 50ml syringe of any brands
4. Preset Solution Volume to greatly reduce the workload of nurses
5. Three work modes: Rate mode, Time Volume mode, Dosage Weight mode
6. Three levels of occlusion: high, middle and low
7. Purge and Bolus function
8. KVO: KVO (keep-vein-open) automatically opens as infusion is completed. And KVO rate can be modified from 0.1ml/h to 10ml/h
9. Freely Stackable: freely stack one onto another to provide multiple Solutions, which have a wide range of clinical applications.
10. Connecting Port for Nurse-Paging
11. Power Source: AC100-240V, 50/60Hz; Internal Battery, DC12V car charge
12. One-key operation makes setup easy and simple
13. Syringe Plunger Grabble Detector, operable with one hand in a No-Germ Environment
14. Automatically record of Infusion, can up to 2000 records
15. HD LCD Display, high capacity words, friendly user interface, dynamically display working status
16. Syringe brand can be displayed, furthermore, syringe specification can be written into the pump
17. language: English, Poland, Latvian, Russian etc
18.Anti-Bolus etc can be available per customers request
19. Voice prompt
20. Drug Library
21. 2000pc patient records
Specification
Injection Speed: 50(60)ml Syringe 0.1ml/h---999.9ml/h (0.1ml/h step)
1000ml/h---1500ml/h (1ml/h step)
30ml Syringe 0.1ml/h---900ml/h (0.1ml/h step)
20ml Syringe 0.1ml/h---600ml/h (0.1ml/h step)
10mlsyringe 0.1ml/h---300ml/h (0.1ml/h step)
Rate Accuracy: within±3% (after correct calibration)
Mechanical Accuracy: within±2%
Purge Rate: 50(60)ml Syringe: 1500ml/h
30ml Syringe: 900ml/h
20ml Syringe: 600ml/h
10ml Syringe: 300ml/h
Bolus Rate: 50(60)ml Syringe: 1200ml/h
30ml Syringe: 720ml/h
20ml Syringe: 480ml/h
10ml Syringe: 240ml/h
Volume Limit: 0.1ml---999.9ml (0.1ml step)
Total Injection: 0.1ml---9999.9ml (0.1ml step)
Occlusion: High 800mmHg±200mmHg(106.7kPa±26.7kPa)
Medium 500mmHg±100mmHg(66.7kPa±13.3kPa)
Low 300mmHg±100mmHg(40.7kPa±13.3kPa)
Alarms: injection soon finish end of injection occlusion improperly
installation of syringe wrong setting low battery etc
Power source: 100V---240V 50/60Hz Internal rechargeable Li battery volume≥1,600mAh 4 hours internal battery backup; DC 12V
KVO Speed: 1ml/h, can be modified from 0.1 to 10ml/h
Power Consumption: 18VA
Operation Environment: a) Temperature +5---+40degree
b)Humidity 20---90%
c)Atmospheric Pressure 86.0KPa---106.0KPa
Storage:a)Temperature -30---+55degree
b)Humidity ≤95%
c)Atmospheric Pressure 50.10KPa---106.0KPa
Dimension: 280mm(L)x 210mm(W)x 130mm(H)
Weight: 2.2KG
Syringe: Compatible with any brand
Drug library: more than 1000 drug names
Package:1pc for each Carton, 3.2KG; 35cm (L) × 28cm (W) × 17cm (H)
2pc carton,6.6KG; 40cm (L) × 39cm (W) × 32cm (H)
3pc carton, 10KG; 59cm (L) × 39cm (W) × 32cm (H)