Flame Photometer

Flame Photometer
Model:AE-SFP40
Brand:A&E Lab
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Optical Lens & Instrument
Label:digital flame photom , flame photometry , photometer
Price: -
Min. Order:1 pc
Inquire Now

Product Description

A & E Lab Hot Selling are include: UV VIS Spectrophotometer, Visible Spectrophotometer, Flame Photometer, PCR-Cycler, Blocker Heater,Hotplate, Stirrer, Stirrer Hotplate, Rotory Mixer, Tube Roller Mixer, 3D Rocker, See-Saw Rocker, Vortex Mixer, Orbital Shaker, Cold Keeper, Melting Point Device, Shaker Incubator, etc.
Welcome to inquire us! 

 

Flame Photometer

Key Features:

Duel channel, LCD display.

Pre-selection of flame sizes;

A flameout protection device;

K and Na testing at the same time.

 

Applications:

Flame Photometer is used for analyzing & measuring the content & concentration of K, Na elements. 

Testing cement, glass, ceramics, refractory materials and other construction materials;

Testing fertilizers and soil;

Testing products of mining, petroleum, metallurgy, and chemical products;

Testing pharmaceutical, beverages and other food;

MSW testing;

Various laboratory tests for scientific research, health, education and other fields.

 

Ordering Information:

Order Code

Description

AE-SFP40

With air-compressor.Measurement Range: 

K: 0-15, 0-40ug/mL;  Na: 0-40, 0-80ug/mL. 

AE-SFP60

With air-compressor. Measurement Range: 

K: 0-15, 0-40, 0-60ug/mL;  Na: 0-40, 0-80, 0-120ug/mL. 

AE-SFP100

With air-compressor, micro-printer or PC software. Measurement Range: 

K: 0-15, 0-40, 0-60, 0-100ug/mL;  Na: 0-40, 0-80, 0-120, 0-160ug/mL.

Technical Specifications:

Linearity Range

K: detection limit ≤ 0.004mmol/L; Na: detection limit ≤ 0.008mmol/L

Linearity Error

K: ≤ 0.005mmol/L(0.01000.0800)mmol/L;

Na: ≤ 0.03mmol/L(0.05000.400)mmol/L.

Repeatability

Conduct 7 consecutive independent tests for one standard solution, 

the relative standard deviation: ≤ 3%.

 

Stability

Continuous sampling of standard solution, the biggest change in the relative volume in 15s: ≤ 3%;

Test once every minute, and test 6 times in total, the biggest change in the relative volume: ≤ 15%.

Response Time

Response time <8s

Suction Jet of Samples

Suction jet of samples <6mL/min

Dimension

380x770x570mm

Weight

18kg

 

Flame Photometer 1

Member Information

A & E Lab Instruments(Guanzhou)Co.Ltd
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:18819139872
Contact:Ella Wu (Sales )
Last Online:30 Jun, 2014