Conveyor Belt Needle Metal Detector

Conveyor Belt Needle Metal Detector
Model:TEB-QS
Brand:TEB
Origin:Made In China
Category:Security & Protection / Safety Products
Label:food metal detector , conveyor detector , medical metal detect
Price: US $2500 / set
Min. Order:1 set

Product Description

Introduction

Our Company engaged in security equipment based on years of research and development production .
In this basis , the introduction of a new generation of microcomputer intelligent high sensitivity, high reliability touch screen interface metal detector .
The product is used in similar products from maintenance and auto-diagnostic function brings great convenience to the user .

Its characteristics and operation are described below:

Features:
(1) New analog circuits and digital circuits combined , greatly improving the reliability and intelligence .
(2) Using the new 5-inch touch screen input and LSI components. The analog signal from the CPU to complete collected and converted to digital for processing and output. Automatic search of the detected metal content matter optimum point , greatly improving the detection sensitivity and reliability.
(3) Use of human interface design. The operation simple and intuitive. HMI glance. All functions operate directly on the screen to complete the perform.
(4) You can set all the necessary functions and modes , and diagnostic functions. Sensitivity: sub-stall , adjustable increase, decrease ( 1-9 stalls adjustable ) , digital large lower sensitivity . Detect trace metals , the sound and light alarm simultaneously , substandard products automatically return to the stop status and exclusion device control separation .

Installation and Maintenance:
1 To prevent accidental electrical shock, do not put debris placed on the equipment, especially electrical connection can not be placed at the.
2 The use of machinery equipment part 220V/50Hz power supply, make sure the power supply voltage is correct.
3 In order to prevent accidents, connect the power supply circuit breaker at the machine, in order to promptly cut off the power.
4 there is flooding in the workplace, the power cord must be connected to an earth leakage circuit breaker.
5 grounding requirements are as follows: copper wire with a diameter of not less than 1.6mm in the ground. Ground resistance must be less than 100 ohm.
6 must be adjusted base adjustment screw to adjust the device steady.
7 should not be near large metal movement, such as mobile carts, metal doors.
8 should not be near the motor or inverter power equipment.
9 shall not be installed in the ground vibration.

Installation Procedure
1. Carefully unpack the equipment placed in the designated qualified installation site.
2. Adjust the base adjustment screw to adjust the device to stabilize, there can not shake
3. Check the screws on the device, whether because of transportation cause loose.
4. Connect the power cord, note the power cord reliable and correct. Power cord connection is recommended to install a circuit breaker to protect the equipment accident moments.
5. Remove all foreign objects around the probe, power, tap the start button, the test machine running observe motor rotation is correct.

Mechanical transmission parts commissioning
1. Power connection open.
2. Place the unit running, set the sensitivity of the closed state is (0).
3. Tap Start by health, motor rotation, observe five minutes, the motor runs smoothly, whether there is a conveyor belt deviation, if there is deviation conveyor belts, conveyor belts, if there is deviation, adjust the output of the two conveyor hex bolts (clockwise rotation belt tight, counterclockwise rotation belts loose. belts tend to side when adjusting the side of tight spots, or the other side of pine point) until the transfer is running smoothly.
4. Pat conveyors, conveyor observed loose, tight is appropriate, whether the conveyor belt and the bottom of the probe friction. If the large loose or big tight regulation also makes two conveyor belt conveyor belt tension adjustment screw to moderate.

simple troubleshooting
1, the conveyor belt deviation
    1) to determine the suitability of the belt tension, if a large conveyor belt loose, easy deviation.
    2) transferred to the pallet holder, near the outlet end of the conveyor belt has two adjusting screws, the belt tension can be adjusted by the two bolts.
    3) observation is consistent tension on both sides, both sides of tension if not, will lead to a conveyor belt deviation.
  4) through the two sides of the tension adjustment bolts and more consistent regulation can solve the problem of the conveyor belt deviation.

2, instrument is not sensitive
   1) Check the probe hole if there is a large metallic foreign body, such as coins, keys, screws, etc.. Exclude metal impurities.
   2) The product selection is correct.
   3) if the detection sensitivity is adjusted to a minimum or if the data collected is too high. When data collection is too high, that this reference voltage and relatively high sensitivity will be reduced. Re-load the collection, if the data is high then turn off the switch at the motor speed controller, so that the motor stopped running for the collection, such as closing the acquisition, such as the motor in the normal range on a conveyor belt, said metal objects or rack bolts loose, to exclude foreign body and tighten the bolts can be solved. If you stop collecting data after the motor rotation may be high voltage detector is surrounded by high-power interference sources, such as vibration or power supply instability, then you can install power supply resolved. If not resolved, please call our Service Department.
  4) When the machine is not installed infrared detector is selected open in the infrared. Close Infrared can be ruled out
  5) If the above conditions are excluded, the detection sensitivity of the instrument still does not, please call our Technical Services Department.

3, Instrument periodically false alarms
    1) conveyor is contaminated by metal impurities, if the conveyor belt by metal impurity contamination whenever contaminated sites through the detection zone, the detector will alarm, cleaning conveyor belts, excluding metal impurities.
    2) Even if the product conveyor hold load testing, the instrument is still cyclical false alarms. At this time there may be around the detector power sources of interference, such as vibration sieve.

4, the motor does not start
    1) Open the control box, "start" on the touch panel and the "stop" button, observe whether the control module relay action, if any action, indicating that motor capacitor motor has been damaged or corrupted. You can buy the same model motor replaced, or contact the company service sectors. Non-professionals are not allowed to repair, to prevent electric shock hazard.
    2) If the relay is no action, you can make the control module is damaged, or the cable is loose, remove the cable loosening, whether observed troubleshooting, if the motor still does not start, please contact the company service sectors. Non-professionals are not allowed to repair, to prevent improper repairs damage to other parts.
Switch 3 observed at the motor speed controller is in the off state. The case can be opened.

5, no electricity
   Observe the power switch in the indicator light does not light, check the power outlet mounted fuse is blown, the power plug is loose, such as blown fuses please send randomly put on standby.

Details

material:201/304 stainless steel
conveyor material:aluminum
detector window high:100 mm
detector window wide:300 mm
operation language:English and Chinese

Conveyor Belt Needle Metal Detector 1Conveyor Belt Needle Metal Detector 2Conveyor Belt Needle Metal Detector 3Conveyor Belt Needle Metal Detector 4Conveyor Belt Needle Metal Detector 5

Member Information

EAST BEST TECHNOLOGY LIMITED
Country/Region:Guang Dong - China
Business Nature:Trading Company
Phone:18929337697
Contact:Connie Kang (Seller)
Last Online:29 Apr, 2014