Applications Industrial instrumentation & process control systems for high temperature media Measured medium high viscosity fluids, melts, compatible with titanium alloys and stainless steel Standard ranges, MPa 0-0,6; 0-1; 0-1,6; 0-2,5; 0-4; 0-6; 0-10; 0-16; 0-25; 0-40 Output 4-20 mA (2-wire) Operating temperature range, H -40... +300 (A-zone of the figure); -40... +80 (C-zone of the figure) ompensated temperature range, H +20 ...+300 Overall accuracy, ±% 0,5 Supply voltage from intrinsic safe supply unit Intrinsic safe supply units MIDA-PSSB-102-Ex, MIDA-ISB-105-Ex, MIDA-ISB-107-Ex,other compatible safe barrier systems Intrinsic safety spark-protected electrical circuit; ExiaIICT1 - ExiaIICT4 Ingress protection IP64 Mounting screw-thread M27 x 2; M20 x 1,5 Electrical connection Sealing gland straight (S) and angle (A); plug/socket (P) Weight no more than, kg 0,6