MS8902 non-contact voltage tester

MS8902 non-contact voltage tester
Model:MS8902
Brand:HY
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Other Electronic Instrument
Label:non-contact tester , dc voltage tester , pen voltage tester
Price: US $588 / pc
Min. Order:1 pc
Inquire Now

Product Description

MS 8902 multifunction process calibrator 

LCD display,,LED back light,Data hold,Diode,Continuity,Insulation test,

auto power off,max value measuring&hold,

DC &resistance& Frequency& Temperature&currency& Duty Cycle&capacity measuring,

Details

Operating temperature

-10to 50

Storage temperature

-20to 70

Operating altitude

3000 meters above mean sea level

Relative Humidity (% RH operating without condensation)

75%(30℃ to 40℃) / 45%(40℃ to 50℃)

35%(50℃ to 55℃) / uncontrolled < 10 °C

Stability

± 0.005 % of range/°C outside of 23 ± 5 °C

Vibration

Random, 2 g, 5 to 500 Hz

Safety

EN 61010-1:1992

Protection Class

Pollution Degree II

Protection ClassL*W*H

224mm*172mm*65mm

Weight

About 1.2kG(Include the battery that accessory)

DC Voltage Measurement

Range

Resolution

Accuracy

0-30.000Vupper display*1

0.001V

0.02%+3

0-24.000Vlower display*2

0.001V

0.02%+3

0-90.000mV *3

0.001mV

0.01%+10

* 1: The signal from the V / mA, COM jack input, * 2 and * 3: The signal from the VΩRTD, COM jack input.

* 1 and * 2: The input impedance higher than 1MΩ.

DC Voltage output

Range

Resolution

Accuracy

0—20.000V

0.001V

0.02%+3

0—90.000mV

0.001mV

0.01%+10

The signal from the VΩ RTDCOM jack output. Maximum load: 1mA.

Millivolt measurement and output

Range

Resolution

Accuracy

-10.000mV—80.000mV

0.001mV

0.01%+10

The maximum input voltage: 30V.

* 1 Press    to select the this function. the signal through to the TC input/output miniplug jack.

DC Current (Milliampere) Measurement

Range

resolution

Accuracy

0—24.000mAupper display*1

0.001mA

0.02%+4

0—24.000mAlower display*2

0.001mA

0.02%+4

Input or output protection: fuse 250V/50mA, fuse resistance is about 6Ω.

* 1: Press the blue button    to select this functions. Signal from the V / mA, COM jack input.

* 2:Press the gray button    to select this function. Signal from the mA-/4W, mA + / 3W jack input.

For Measurement, the sampling resistance: 10Ω.

DC Current (Milliampere) Output

Range

Resolution

Accuracy

0—24.000mA

0.001mA

0.02%+4

SIMU  (Simulating) output current, the external voltage higher than 12V, lower than 28V.

SOUR (Sourcing) output current, the signal drive capability: 1000Ω at 20mA.

Input or output protection: fuse 250V/50mA, fuse resistance is about 6Ω.

Press the gray button     to select the this functions. Signal through to mA-/4W, mA + / 3W jacks.

Ohms Measurement

OhmsRange

Accuracy ±Ω

4-wire4W

2-wire2Wand 3-wire3W

0—400.00Ω

0.1Ω

0.15Ω

400.0—4000.0Ω

0.5Ω

Excitation Current: 0.2mA.Maximum input voltage: 30V.2-wire: Does not include lead resistance.

3-wire: Assumes matched leads with a total resistance not exceeding 100 Ω.

Ohms Source

Range

Excitation Current from Measurement Device

Accuracy ±Ω

Resolution

5.00Ω to 400.00Ω

0.15mA-0.5mA

0.1Ω

0.01Ω

5.00Ω to 400.00Ω

0.5mA-2mA

0.05Ω

0.01Ω

400.0 to 1500.0Ω

0.05mA-0.8mA

0.5Ω

0.1Ω

1500.0Ω to 4000.0Ω

0.05mA-0.4mA

0.1Ω

Temperature ,Thermocouples

Type

Range

Resolution

Measurement and Source Accuracy±℃

 

S

 

-50.0℃to 0℃

0.1℃/0.1℉

1.5℃

0℃to 500.0℃

0.1℃/0.1℉

1℃

500.0℃to 1760.0℃

0.1℃/0.1℉

0.8℃

 

R

 

-50.0℃to 0℃

0.1℃/0.1℉

1.5℃

0℃to 500.0℃

0.1℃/0.1℉

1℃

500.0℃to 1760.0℃

0.1℃/0.1℉

0.8℃

B

 

200℃to 800℃

800℃to 1800℃

 

1℃/1℉

2.2℃

1.8℃

K

-200.0℃to 1370.0℃

0.1℃/0.1℉

0.8℃

N

-200.0℃to 1300.0℃

0.1℃/0.1℉

0.8℃

E

-200.0℃to 1000.0℃

0.1℃/0.1℉

0.5℃

J

-200.0℃to 1200.0℃

0.1℃/0.1℉

0.5℃

T

-200.0℃to 400.0℃

0.1℃/0.1℉

0.5℃

The thermocouple complies with ITS-90.

If open the cold junction compensation (CJC ON), additional plus ± 0.3 ℃.

Temperature ,Resistance Temperature Detectors (RTD)

Type

Range

                    Accuracy±℃

Measure 4-wire℃

Measure 2-wire and 3-wire℃

Output℃

Pt100-385

-200.0℃-850.0℃

0.3℃

0.5℃

0.3℃

Pt100-3926

-200.0℃-850.0℃

0.3℃

0.5℃

0.3℃

Pt100-JIS

-200.0℃-850.0℃

0.3℃

0.5℃

0.3℃

Pt200-385

-200.0℃-250.0℃

0.2℃

0.3℃

0.2℃

250.0℃-630.0℃

0.8℃

1.6℃

0.8℃

Pt500-385

-200.0℃-500.0℃

0.3℃

0.6℃

0.3℃

500.0℃—630.0℃

0.4℃

0.9℃

0.4℃

Pt1000-385

-200.0℃-100.0℃

0.2℃

0.2℃

0.3℃

100.0℃-630.0℃

0.2℃

0.3℃

0.3℃

Cu100

-50.0℃-150.0℃

0.4℃

0.6℃

0.4℃

Cu50

-50.0℃-150.0℃

0.4℃

0.6℃

0.4℃

Resolution: 0.1 ° C, 0.1 ° F.

Allowable excitation current (Source): Pt100-385, Pt100-392, Pt100-JIS, Pt200-385: 0.15 to 3.0 mA

Pt500-385: 0.05 to 0.80mA; Pt1000-385: 0.05 to 0.40mA.

* 2-wire: Does not include lead resistance.

*3-wire: Assumes matched leads with a total resistance not exceeding 100 Ω.

Accessories:

The items listed below are included within the packaging aluminum box.

the Calibrator is damaged or missing something, contact with the supplier immediately. Contact to the supplier to order replacement parts or spare parts please.

. Test Leads                                              1 pair

  .A pair of alligator clips test lead.                            1 pair

. Power Adapter                                           1

. Ni-MH rechargeable battery 1.2V AA                        8

.Spare fuse                                               3

.User manual                                              1

Remind:

Do not operate the Calibrator around explosive gas, vapor or dust. Do not make the Calibrator be exposed to Glare and high temperature or moisture.

Do not operate the Calibrator around explosive gas, vapor or dust. Do not make the Calibrator be exposed to Glare and high temperature or moisture.

.

Warranty: One Year.

Any quality problem occurs whitin 7 days after you receive the goods,you can ask for replacement or refund as long as it is not damaged by personal mistake.

Shippment&Payment:

We usually shipped by air,such as DHL,UPS,FedEx,China post mail,EMS,TNT and etc as you like,shipping day is about 4 days or more depends on your order quantity, and the delivery day is about 20-40 days by EMS and post mail,by others it is within 20 days. We usually write gift on the packing with a low value to help you reduce the tax,however different countries have different rules, if you refuse to pay the tax at your country,the goods will be returned to us,you have to bear the loss.

As to payment, you can pay by T/T and western union as you like, we will ship the goods only after we get your full payment.

 

MS8902 non-contact voltage tester 1

Member Information

Shenzhen Huayi Technology Co. Ltd
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:13872175283
Contact:Alina Lee (Sales Manager)
Last Online:28 Dec, 2015