Model: | GM8802C-S |
---|---|
Brand: | GM |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Other Electronic Instrument |
Label: | Weighing indicator , weighing transmitter , weight indicator |
Price: |
US $200
/ pc
|
Min. Order: | 1 pc |
GM8802C-S Linear vibration controller is specialized in packaging system with vibration plate feeding mechanism, which is suitable for small bags with specification of 10.0-5000.0g, so it can be widely applied to powdery and small uniform particles like sugar, salt, seed, grain, milk powder, coffee etc.
Key Features:
Small dimension, handsome appearance, easy to operate.
Suit to all kinds of resistance strain gauge bridge load cell
Multilevel of digital filter
Automatic zero tracking
Single, double vibration plate mode (optional)
Fast speed, high precision
Self-adaptive parameters
Self-test vibration plate feeding control voltage
INIDICATOR POWER | |
Power Supply | DC 24V ± 5% |
Power Consume | About 4W |
A/D CONVERTER | |
Type | 24-bit Delta-Sigma |
Analogue input range | 0mV to 15mV |
Linearity | <0.01%FS |
Gain Drifting | 10PPM/degree |
Minimum Sensitivity | 0.06 µ V/d |
Conversion Rate | 120/240/480/s |
D/A resolution Ratio | 12bits |
CALIBRATION & WEIGHING FUNCTIONS | |
Calibration | By test weight or by electronic calibration |
Digital Filter | Two Layer FIR filter with 9 selectable levels |
Weighing Functions | zero, zero tracking, auto-zero at power |
DISPLAY | |
Status Indicator | AD, RS485 |
ENVIORNMENTAL | |
Operating Temperature | -10 degree to 40 degree |
Storage Temperature | -25 degree to 70 degree |
Relative Humidity | 90% R.H without dew |
IP Level | IP 20 |
LOAD CELLS | |
Excitation | DC5V 125mA(MAX) |
Load Cells | Drives 8pcs load cells 350Ω |
MECHANICAL DATA | |
Dimensions & Weight | 82×92×45mm (L×W×H) weighs approx.320g |
Standard Mounting | DIN Rail |
Certification | CE |
Enclosure | Aluminum |
DIGITAL INPUT | |
Output Number | 5 |
Output Meaning | (5 Self-defined meanings) Discharge L, Fix weight, Fine feeding vibration plate, Coarse feeding vibration plate, Discharge M. |
DIGITAL OUTPUT | |
Output Number | 4 |
Output Meaning | (4 Self-defined meanings) Start, Stop, Permit discharge, finished level. |
INSTRUMENTS WITH DATA TRANSMISSION | |
Serial Interface RS485 | Baud rate 38400 |
Communication Mode | Modbus RTU |
Shenzhen General Measure Technology Co., Ltd. | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 27484266 |
Contact: | Nancy Xu (International Sales) |
Last Online: | 29 Jul, 2014 |