Model: | QA-6000 |
---|---|
Brand: | idealphotonics |
Origin: | Made In Canada |
Category: | Electronics & Electricity / Telecommunication & Broadcasting / Network Communications Equipment |
Label: | Quartz Flexure Accel , Accelerometers , Quartz Accelerometer |
Price: |
US $15000
/ pc
|
Min. Order: | 1 pc |
Q-FA® QA-6000 Accelerometer
The inertial navigation standard
Description
As the inertial navigation standard by which others are measured, Idelphotonics produces the QA6000. It is the predominant sensor used in today’s commercial and military aircraft strap-down inertial navigation systems. The long-term Repeatability and superior reliability characteristics of the QA6000 make it the best value inertial-grade accelerometer available on the market today.Also this is highest precious product in the market today.
As with the entire Q-FA family of accelerometers, the QA6000 features a patented Q-FA® etched-quartz-flexure seismic system. An amorphous quartz proof-mass structure provides excellent bias, scale factor, and axis alignment Repeatability.
The integral electronics develops an acceleration-proportional output current providing both static and dynamic acceleration measurement. By use of customer supplied output load resistor, appropriately scaled for the acceleration range of the application,the output current can be converted
into a voltage.
Features
• Excellent turn-on repeatability performance
• Environmentally r ed
• Analog output
• Field-adjustable range
• Three fastener precision mounting flange
• Internal temperature sensor for thermal compensation
• Dual built-in self-test
Configuration Drawings
Performance Characteristics
Performance |
QA6010 |
QA6020 |
QA6030 |
QA6050 |
QA6080 |
||||
Input Range [g] |
>40 |
>40 |
>40 |
>40 |
>40 |
||||
Bias [mg] |
<5 |
<5 |
<5 |
<5 |
<5 |
||||
Three month Composite Repeatability [µg] |
<10(six month) |
<20 |
<30 |
<50 |
<80 |
||||
Temperature Sensitivity [µg/ºC] |
<10 |
<20 |
<30 |
<50 |
<80 |
||||
Scale Factor [mA/g] |
1.1±0.10 |
1.1±0.10 |
1.1±0.10 |
1.1±0.10 |
1.1±0.10 |
||||
Six month Composite Repeatability [ppm] |
<10 |
<20 |
<30 |
<50 |
<80 |
||||
Temperature Sensitivity [ppm/ºC] |
<10 |
<20 |
<30 |
<50 |
<80 |
||||
Axis Misalignment [µrad] |
<500 |
<500 |
<500 |
<500 |
<500 |
||||
0g 4h stability [ug] |
<10 |
<20 |
<20 |
<20 |
<20 |
||||
1g 4h stability[ug] |
<10 |
<20 |
<20 |
<20 |
<20 |
||||
Hysteresis circle[ug] |
<60 |
<60 |
<60 |
<60 |
<60 |
||||
Electrical noise(840Ω)[mv] |
<8.4 |
<8.4 |
<8.4 |
<8.4 |
<8.4 |
||||
Power on/off Composite Repeatability[ug] |
<20 |
<20 |
<20 |
<20 |
<20 |
||||
Environment |
QA6010 |
QA6020 |
QA6030 |
QA6050 |
QA6080 |
||||
Operating Temperature Range [ºC] |
-55 to +95 |
-55 to +95 |
-55 to +95 |
-55 to +95 |
-55 to +95 |
||||
Shock [g]Half sine |
50,8-12ms |
50,8-12ms |
50,8-12ms |
50,8-12ms |
50,8-12ms |
||||
Vibration [g] 20~2000HZ |
10 @ 20-2000 Hz |
10@ 20-2000 Hz |
10@ 20-2000 Hz |
10@ 20-2000 Hz |
10@ 20-2000 Hz |
||||
Resolution/Threshold [µg] |
<5 |
<5 |
<5 |
<5 |
<5 |
||||
Natural frequency [Hz] |
400~800 |
400~800 |
400~800 |
400~800 |
400~800 |
||||
cut-off frequency[Hz] |
<2500 |
<2500 |
<2500 |
<2500 |
<2500 |
||||
Overshoot[%] |
<40 |
<40 |
<40 |
<40 |
<40 |
||||
the number of Half shocks |
<3 |
<3 |
<3 |
<3 |
<3 |
||||
Concussion |
<1.68 |
<1.68 |
<1.68 |
<1.68 |
<1.68 |
||||
Concussion rectification error(0g,1g) [µg] |
100HZ,200HZ,3g:<80;500HZ,3g:<120 |
||||||||
Input Voltage [V] |
+15±3,-15±3 ±13 to ±28 ±13 to ±28 |
||||||||
Physical |
QA6010 |
QA6020 |
QA6030 |
QA6050 |
QA6080 |
||||
Weight [grams] |
80 |
80 |
80 |
80 |
80 |
||||
Case Material |
300 Series Stainless Steel |
300 Series Stainless Steel |
300 Series Stainless Steel |
300 Series Stainless Steel |
300 Series Stainless Steel |
Find out more: Fiber optic gyroscope solution Defense & Space Redmond Idealphotonics, Inc. Suite 1525 – 555 Burrard Street, Box 226 Vancouver,BC,Canada, V7X 1M9 Email:info@idealphotonics.com EXP028, June 2005 Copyright © 2004, Idealphotonics Inc. All Rights Reserved. Printed in Canada |
ISO-9001 Certification Since 1995 DISCLAIMER: Specifications are subject to change without notice.Idealphotonics reserves the right to make changes to any product or technology herein to improve reliability, function, or design. IDP does not assume any liability arising out of the application or use of the product.
|
Payment Terms: | TT |
---|---|
Idealphotonics Technology(Hongkong)LIMITED | |
---|---|
Country/Region: | Hong Kong S.A.R |
Business Nature: | Manufacturer |
Phone: | 3918813416 |
Contact: | Yoshi (Sales) |
Last Online: | 21 Oct, 2014 |