Product Description

WBB series high voltage reactive power compensator

 

Ⅰ. General

WBB series high voltage reactive power compensator is a capacitive reactive power compensator for improving the power factor, adjusting the voltage and lowering the consumption of the network, which is mainly applicable to the electric power system of voltage class 6KV to 10KV.

Because most of the loads in the electric power system are perceptual and more and more power electron equipments are used in industrial and mining enterprises, the power factor of the electric network is quite low. The lower power factor reduces the use factor of the equipment, while increases the investment of the power supply and the line loss, as well as harms the quality of the voltage and shortens the service life of the equipment.

To improve the factors unbeneficial to the production caused by quite low power factor of the electric network, must improve efficiently the power factor of the electric network. Obviously, if these reactive power are all supplied by the generator and transmitted by distant is not reasonable, also impossible in usual. The reasonable method is to produce the reactive power where it is required. Most of the loads are asynchronous motors in the actual electric power system. Its equivalent circuit can be taken as the series circuit of the resistance and the inductance, while its phase position of the voltage and the current is bigger with lower power factor. After parallel connecting the capacitor, the phase position of the voltage and the current become smaller in order to improve the power factor.

WBB series high voltage reactive power compensator is widely used in metallurgymining, construction, petrochemical industrial and mechanism and so on for local compensation for large power high voltage motors and for the centralized compensation for the distribution system.  

 

Ⅱ. The problems can be solved by WBB

When you meet the following problems, WBB series high voltage reactive power compensator produced by our company can effectively solve the problems for you to get you satisfactory results.

1. The power factor of the enterprise electric network is low and the enterprise has even been punished by the power supply bureau. The power factor needs to be improved.

2. The voltage of the enterprise substation is low, and the voltage of the electric network needs to be increased.

3. The line loss of the transmission circuit is too large. It needs to be reduced to save the cost on the transmission circuit and the consumption of the transformer needs to be reduced to save the electric energy.

4. Electrical equipments put to use lately, the compensation of reactive power needs complement.

5. The output power of the equipment can not reach the rated power because of the low power factor.

6. The quondam compensator is too old to meet the techniques requirement

7. The load increased, but the quondam capacity of the transformer or the quondam distribution circuit can not meet the requirement because of the over consumption of the reactive power. The apparent output of the power supply needs to be reduced to increase the supply capacity.

8. The voltage of the electric network is sometimes high and sometimes low, which affects the operation of the equipment.

9. The perceptual loads (like motor) in the output system of the transformer are many, while the compensation units are required.

10. The power factor of the enterprise electric network is low. The power factor needs to be improved and the circuit current needs to be reduced to prolong the service life of the electrical equipments. And the section specification of the conducting wire needs to be reduced to save the investment.

 

. Performance characteristics

1. Adopting high quality brand elements and advanced design, long service life of the products

2. Reasonable arrangement and humanization design, with convenient operation, usage and maintenance

3. Own discharging unit protects the safety of the human body and the equipment.

4. With the functions of open triangle, over current and over load protection and so on make the operation safe and reliable.

5. Adopting vacuum electroplating film metal polypropylene film parallel connecting capacitor, with low self-consumption because of the high service field density, low medium consumption, small volume, large capacity, low consumption and light weight and so on features of the polypropylene film

6. The deviation of the actual measuring capacity from the rated value does not exceed +10to -5% of the rated value.

7. The series reactor can be added to limit the impulse in switching-on process of the capacitor bank and to limit the operation over voltage as well as to suppress the influence of the upper harmonic on the capacitor in the electric network.

8. Obvious energy saving results: Improve the power factor to more than 0.95, and reduce the current to 10%~20%,as well as reduce the line loss efficiently. 

9. Low own consumption: The capacitor used in this device is with extreme little energy loss which is less than one fifth of the usual oil low capacitor.

10. With mature consideration of the actual condition for the user, the capacitor bank of the local compensator and the relative control unit are placed in the same cabinet for the convenient installation and usage of the single machine of the high voltage motor local compensating.

 

VI. Order notice

The following items must be stated clear during ordering

1. The rated voltage, the rated power, the condition of load variety, and the power factor both before and after compensation.

2. The cabinet color, dimension of the cabinet body and other relative special requirements.

3. The type of the cabinet, quantity and the operation voltage of the secondary circuit and so on.

4. The switching mode of the capacitor and the hardware configuration.

5. Declare it specially if the normal environment condition can not be met.

6. The primary voltage and the variety scale of the current transformer.

 

VII. Use environment 

The use environment of the reactive power compensator shall meet the following requirements:

1. Indoor using with good-ventilation.

2. Indoor installation with height above sea level ≦ 1000m. No serious mechanical shake, no harmful gas or dust and no conducting or explosive dust.

3. Long-term over-voltage (no more than 4 hours within 24 hours) shall not exceed 1.1 Un; Long-term over current (including the harmonic wave) not exceeds 1.35In.

4. Environment temperature: ambient temperature is not more than +40 and the lowest temperature when the capacitor is inputting is -40.

5. Atmosphere condition: The relative humidity when the temperature is +40 shall not exceed 50%; a higher humidity is allowable when the temperature is lower and freezing may occur for the temperature changing has to be considered.

6. The installation inclination pitch can not be more than 5°.

7. No rain or snow attack on the installation site. No severe mildew or erosive gas.

8. The harmonic content on the electric network is subject to the national standard.

If the user’ site can’t meet the above “using environment” requirements, please contact our company to do some special design.

 

VIII. Field mounted

The following prepare work shall be done before our technician’s arrival:

1. Get the compensator ready, and fix it above the cable trench by channel steel as well as determine the inlet and outlet position of the cables. 

2. Prepare the cables (the line width shall bear the current of the capacitor) for the connection of the electric network and the cables of the compensator. Finish making the terminal joints.

3. Get the signal lines (1.5mmcopper core cables) ready: Zero line is for low voltage and AC220V power supply while power cord (2.5 mm2 copper core cables) is for high voltage.

The work need to be done by our technician:

    1. Give guidance on the installation and commissioning on site.

    2. Descript the operation method and precautions to the operation staff.

    3. Give technically training to the user’s technician.

    4. Introduce the service after sale of our company.

5. Listen and take down the opinions and s estions from the customer. Report them to the relative department in time.

 

IX. Safe operation and precautions

l. Before opening the cabinet door, the circuit breaker or the isolating switch must be switched off to let the discharging unit of the capacitor discharge automatically, and then the door can be open three minutes later. After opening the door, manual discharging is also necessary.

2. The capacitor makes special noise in the operation process is the breakdown presymptom of the inner insulation, immediately stop and inspect the capacitor.

3. The shell of the capacitor expands is because of the dielectric decomposition bubbing caused by overvoltage, immediately stop and inspect the capacitor.

4. The capacitor inputting at once after switching off is prohibited to avoid the serious damage to the other electrical equipments as well as to the capacitor itself. Usually the time interval of more than 3 minute is necessary. For the automatic switching capacitor, if the change of the electric power factor is quick, the delay time shall be prolonged accordingly.

5. The capacitor may have an amplification effect on the harmonic wave. The user shall state the conditions of the harmonic of the enterprise for us to make special treatment. Inspect the capacitor ever and again in the operation process. Switch off without delay if there is any abnormity.

6. The good-ventilation both inside and outside the capacitor cabinet is necessary to prolong the service life of the capacitor.

7. Keep the surface of the capacitor clear to avoid any flashover accident.