Handheld Pulse Oximeter

Handheld Pulse Oximeter
Model:pulse oximeter
Brand:Sinnor
Origin:Made In China
Category:Electronics & Electricity / Other Electrical & Electronic
Label:pulse oximeter , oximeter , oximetry
Price: -
Min. Order:5 pc
Inquire Now

Product Description

Features

Lightweight for carrying and Easy-To-Use.

Silicon rubber shell protection and stable bracket.

Using DB9 type connector compatible with Nellcor Spo2 Sensor.

Support the oximeter probe for adult, neonate and infant.

2.8” color TFT show SPO2/PR/Pulse bargraph/ plethysmogram.

Visual and sound alarm function.

Adjust the parameters in friendly menu.

Low Battery voltage indicator.

Auto switch off no signal within 3 minutes.

Inner memory for 360 hours.

USB interface upload the data to PC and review

Standard 4×AAA 1.5V Alkaline bаttеrу or rechargeable Li battery

 

General

Monitoring Parameters: SpO2\PR\Body temperature (Optional)

Signal sockets: SpO2 socket\USB socket\ Temperature sensor socket.

Display screen: 2.8 inch TFT LCD

Display area: 58mm×43mm

Size: 133mm (L) x62mm (w) x22mm (H)

Weight: 90g (not include probes and battery)

 

Electrical specifications

Working voltage: DC4.0V-6.0V or 3.5V-4.2V Li battery.

Internal battery: 4 AAA alkaline battery or 1800MAH rechargeable Li battery

Run time: 15-hour continuous operation with a new, fully charged battery (environment temperature is 25℃)

 

Environment

Temperature

Operation: 10℃-45℃; Transportation and storage: -20℃-60℃

Humidity

Operation: 15%-95%(no condensing); Transportation and storage: 10%-95%(no condensing)

Altitude

Operation: 86KPa-106 KPa; Transportation and storage: 50KPa-106 KPa

 

Parameter Specifications

SpO2

Patient: adult, child

Hemoglobin saturation display: 35%-99%

Resolution:1 %

Accuracy: ±2%(70%-99%)  unspecified(0%-69%)

PR 

Range: 0bpm-250bpm

Resolution: 1bpm

Accuracy: ±1bpm

Power Consumption: Smaller than 80mA(Normal)

Low perfusion Condition 0.3%

Temperature

Channel                                      1

Measuring and Alarm Range         18 ~ 45 °C

Resolution                                  0.1°C

Accuracy                                    ±0.1°C

Actualization interval                   about 1 Sec.

Average Time Constant                < 10 Sec.

Payment Terms:TT
Handheld Pulse Oximeter 1Handheld Pulse Oximeter 2

Member Information

Sinnor Instrument Inc
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:18682356334
Contact:Mandy (Marketing)
Last Online:19 May, 2017