Model: | BPM-9630 |
---|---|
Brand: | Bestmna |
Origin: | Made In China |
Category: | Services / Therapies |
Label: | Patient monitor , ECG monitor , monitor equipment |
Price: |
-
|
Min. Order: | 1 pc |
BPM-9630 Multi-Parameter Patient Monitor
12.1''high resolution color TFT display
96 hours graphic trend
Pacemaker detection, arrhythmia , S-T segment analysis
Digital SpO2 technology with better , performances of anti-electrosurgical , interference, anti-motion and anti-low infusion
Calculation function of drug concentration, drug titration and hemodynamic status
Wired or wireless network
Three-level Audible and visible alarm , events recallable
Nurse Call function
For adult, pediatric and neonate
Standard configuration: ECG,RESP,NIBP,SPO2,PR,TEMP
Optional function: IBP,EtCO2,Cardiac output,printer
Specification:
Dimension: 272(H) X 327(W) X 145(D) (mm)
Weight: 6.5Kgs (with battery)
ECG
Measuring range: Adult 0~300bpm
Neonate and pediatric 0~350bpm
Band width: 0.05Hz~100Hz
Accuracy: ±1%
Lead Type: 5-lead and 3-lead selectable
Lead selection: standard I,II,III; augmented limb lead
aVR, aVL, aVF;Chest lead V1~V6
Resolution: 1 bpm
Trend monitoring time: no less than 96 hours
ST-Segment analysis: -2.0 mV ~2.0mV; auto
Arrhythmia analysis: 13 kinds of Arrhythmia analysis
Scanning speed: 12.5, 25, 50mm/Second
Gain selection: x1/2, x1, x2; auto
Protection: Withstand 4000 VAC/ 50Hz voltage
Voltage in isolation against
Defibrillation and electrosurgical
interference
ECG cable : adults, pediatric and neonate
Alarm Range: 15-350 bpm
ARR Alarm: Audible and visible alarm ,
events recallable
NIBP
Method: Automatic Oscillometric
Operation Model: manual, automatic, continuous
Auto measurement
time interval: Adjustable 1 /2 /3/4
/5/10/15/30/60/90/120/240/480 Min.
Measuring Unit: mmHg /kPa selectable
Measurement types: Systolic, Diastolic, Mean
Measuring Range: Adult: 10~270mmHg
Pediatric: 10~200mmHg
Neonate : 10~135mmHg
Cuff pressure range : 0~320mmHg
Cuff type: Adult cuff
Pediatric
Neonate
Cuff inflation time: < 10 seconds
Cuff deflation time: <20 seconds
Over-Pressure
Protection: Yes
Alarm: Upper alarm,lower alarm,Auto-memory
TEMP
Measuring range: 0~ 50 ℃ ( 32~122℉ )
Probe Type: Body temperature probe (standard)
Esophageal temperature probe (Optional)
Rectal Temperature probe (Optional)
Resolution: 0.1℃
Accuracy: ±0.1℃
Channel: Dual-channel, Provide T1, T2
Alarm Range: 0~50℃
SpO2
Measuring range 0~100%
Resolution: 1%
Accuracy: ±1% ( 70%~100%)
±2% (0%~69% )
PR measuring range: 0~255 bpm
PR accuracy: ±1 bpm
Sensor Type: Adult sensor (standard)
Pediatric sensor(optional)
Neonate sensor(optional)
Alarm Range: 0~100%
RESP
Display: waveform display and numeric display
Operation Mode: Auto/Manual
Method: Trans-thoracic impedance
RR Measuring range: 0~150bpm
Accuracy: ±1 bpm
Apnea alarm threshold: 10s,15s,20s(default),25s,30s,40s
Band Width: 0.2-2.5Hz (-3dB)
Sweep speed: 6.25mm/s,12.5mm/s,25mm/s,50mm/s
Alarm Range: Adult:6-120rpm
Pediatric and Neonate:6-150rpm
IBP (Optional)
Measurement range: - 10 ~ 300 mmHg
Channel: 2 channels
Sensitivity: 5 μ V/V/mmHg
Impedance range 300~3000Ω
Accuracy: ±1 mmHg or ±2%
(exclusive of transducer)
Alarm Range: -10 ~ 300 mmHg
EtCO2 (Optional)
Measurement range: 0 ~ 300 mmHg
Accuracy: 1rpm
Sample flowerate: 50 ml/min
Sample rate accuracy ±15% or 15 ml/min.
Respiration rate: 0 ~ 120 rpm
Respiration accuracy: ±2 rpm (0 ~70 rpm)
±5 rpm (>70 rpm)
Respiration time: < 60 ms
Delay time: <2s