Model: | INS-D033 |
---|---|
Brand: | INLINS |
Origin: | Made In China |
Category: | Home Supplies / Personal Care Appliance |
Label: | Acne softlaser , Laser acne , Acne removal |
Price: |
US $11.3
/ pc
|
Min. Order: | 500 pc |
INS-D033
INS-D033 is a soft laser that is truly an innovative and advanced solution to most of today’s skin rejuvenation problems. This personal-use low level laser is totally safe, gentle, non-invasive and very effective.Used commonly throughout Europe and at the hottest spas around the world, low level laser therapy has no side effects, adverse reactions, produces no heat or discomfort, and the results are commonly seen within dasoft laserys to weeks.
The Soft Laser™ uses the same modern and breakthrough technology that many of today's top medical professionals pay thousands of dollars for, but is now available to use in the privacy of your home (or wherever you wish; the small laser can be taken anywhere with the provided travel case and treatments last an average of 5 minutes) for a fraction of the price.
Main Features
1. mini Acne Softlaser for home use
2. Excellent for cure Acne
3. Care your skin easy at home
4. Easy and safe to operation
5. CE approval
Home use Acne Softlaser soft laser equipment INS-D330
Treatment with the Softlaser provides the body cells with a defined biological
energy.
Technical Data:
Unit class: Low-level laser class 3 A
Laser: GaALAs (Gallium-Aluminium-Arsenide) diode, continuous beam
Power output: max. 10mW
Laser wavelength: 635-670nm
Power supply: 2×1.5 Valkaline batteries (“micro”: AAA/IEC Type LR 03)
Rated voltage: 3V DC
Operating mode: Continuous operation
Class of protection: internal supply
Explanation of symbols: Read Instructions for Use!
Mode of Action
The Softlaser radiation provides the principal energy sources of the skin cells
(knows as mitochondria) with energy, stimulating increased production of ad-
enosine triphosphate (ATP). This in turn increases the regenerative power of
the cells. Treatment with the Softlaser provides the body cells with a defined
biological energy.
The effect of the Softlaser begins at cellular level. However, the regeneration
processes will take a little time before the result can be seen. When the unit is
used correctly, an improvement in the condition will be noticed within a few d-
ays. However, treatment should be carried out for a least a week.
If the symptoms do not improve or subside within 3-4 days of treatment (in s-
pite of using the laser unit in accordance with instructions) please consult your
doctor. All of the skin conditions for which the unit can be used may require r-
epeated treatment. In general, after repeated treatment you will see that the
condition becomes less severe each time it recurs. Treatment must be carried
out for between 15 and 30 minutes every day.
Uses:
Herpes (lip or fever blisters) / Inflammations of oral mucosa (mucous membranes
of the mouth)
Herpes- triggered by the herpes simplex virus- is an infection of the skin and mucosa
and tends to recur at intervals. The virus is widespread and is transmitted through
droplets or direct contact. Initial infection generally occurs in early childhood. The
virus then remains dormant in the body until it is triggered by stress factors such
as feverish infections, psychological stress or physical over- exertion (energy de-
ficiency) and exposure to high levels of UV light etc.
Herpes usually appears as small vesicles in the area around the lips or, in special
cases, symptoms may occur in the form of Aphthae, an inflamed mucous memb-
rane of the mouth. Skin cells which are affected by the herpes virus have many di-
fferent mechanisms which are especially suited for dealing with the virus and these
are triggered by acute infection. For this, the skin cells require cell energy which is
promoted by the Softlaser.
Treatment: Hold the Softlaser approximately 1 cm from the affected area. Do not
hold the unit directly against the skin.
Inflammations of the angle of the mouth, chapped lips, chafed skin
These conditions, if they fail to heal over a longer period, can also be successfully
treated using the Softlaser and the healing mechanism of exhausted cells can be
optimized. Treatment: Hold the Softlaser approximately 1 cm from the affected area.
Do not hold the unit directly against the skin.
Acne
The severity of acne can vary considerably from person, so it is necessary to use
different, methods of treatment. If the acne is severe, then you should consult a
doctor and cosmetic therapy may be necessary. Treating acne with the Softlaser
will not prevent it from appearing or alter its normal course. However, if used con-
sistently, the Softlaser can have a beneficial effect on the inflammation.
Treatment: if the spots have appear recently and are still open then hold the Sof-
tlaser 1 cm from the affected area; if the spots are closed and dry then the Softl-
aser may be held directly against the skin.
Small scars, wrinkles
The unit may help in treating small scars and wrinkles.
Treatment: For this purpose, the Softlaser can be used directly on the skin. Caution:
When using the unit near the eyes, make sure that the laser beam does not shine on
to the eye.
Colds
Colds are usually caused by viruses. The defence systems of the mucous membr-
ane of the nose and other orifices near the nose are triggered by the infection. Tre-
atment with the Softlaser helps the cell of the mucous membrane produce more e-
nergy (ATP).
Treatment: Hold the Softlaser approximately 1 cm under each nostril but do not pu-
sh the instrument into the nose. Disinfect the unit after use.
Usage:
Battery
To open the battery compartment push the cover in the direction indicated by the
arrow. Ensure correct polarity when inserting the batteries (the polarity is marked).
To close the battery compartment push the cover in the opposite. Battery disposal:
You are legally obliged to dispose of the batteries. Used batteries do not belong
in the house hold waste. Dispose of them via your specialist electrical supplier or
local collecting point for recyclable waste. Note: Batteries containing pollutant
substances are marked as follow: Pb = Battery contains lead, Cd = Battery contains
cadmium, Hg = Battery contains mercury.
On/Off
The Softlaser is turned on and off by pressing the “On/Off” button.
Cleaning
It is recommended that the laser head be cleaned after each treatment with com-
mercial isopropyl alcohol. Wet a cloth with the alcohol for cleaning the unit, do not
immerse the laser head completely in alcohol. Ensure that the Softlaser is comp-
letely dry before using it again.
Important information – please keep for later use.
l Read these notes carefully
l Looking directly into the laser beam, even when using optical instruments, could
lead to irreversible damage to the eye. If this happens, immediately consult an eye
specialist. The unit is a Class 3 A laser.
l Do not use on small children or vulnerable individuals.
l Patients who have previously had a face lift must consult their skin specialist before
using the Softlaser.
l If you are uncertain about its use, we recommend you consult your doctor.
l The laser beam must not be directed against other persons.
l The laser unit must be stored out of the reach of children
l The laser unit must be secured against improper use by unauthorised persons.
l The unit should not be used with anaesthetic gases or flammable substances.
l The batteries should be removed if the unit is not to be used for some time. R-
eplace batteries once the unit has been used approximately 100 times.
l The visible metal parts are manufactured from medical-grade steel. If used and
cleaned correctly no allergic reactions are therefore to be expected.
l Repairs may only be carried out by the specified authorized repair centers. Caution:
Incorrect handling and faulty repairs may lead to a dangerous exposure to radiation.
l The laser unit must not be used in clinical areas or in the vicinity of strong electro-
magnetic fields (e.g., close to radiation units or mobile telephones etc.).
Payment Terms: | T/T, Paypal, Western Union, MoneyGram |
---|---|
Shenzhen Inlins Technology Co.,Ltd | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 14795405952 |
Contact: | Christine Lee (Sales Representative) |
Last Online: | 30 May, 2016 |