Model: | - |
---|---|
Brand: | - |
Origin: | Made In Ukraine |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | Insulation Testing , High voltage test sy |
Price: |
US $4530
/ pc
|
Min. Order: | 1 pc |
High voltage test system HVTS-70/50 is designed for testing the insulating properties of power cables and solid dielectrics with a rectified voltage of up to 70 kV, and solid dielectrics with sine-wave voltage of up to 50 kV at 50Hz frequency in accordance with GOST 1516.2.
The test system HVTS-70/50 is:
- Supplies the high voltage test on the object and control of leakage current;
- Ensures high accuracy and maintenance of the test voltage at a certain level, it is possible to adjust the leakage current with an external capacitor additional DC voltage during the test;
- Measures the voltage directly at the load, allowing you to have a real idea about the stress tests on the object and control it with the specified accuracy. In addition, significantly increasing the safety of the staff, especially when removing the residual capacitive charge when disconnecting the high voltage;
- Made in a sealed enclosure provides protection for remote control from dust and moisture, which is especially important when using the machine in the field;
- A protection scheme on excess input and output current limit and set the output voltage exceeds the set. HVTS-70/50 has the ability to program required for a particular test value of the maximum current and maximum voltage protection circuitry;
- High voltage unit has a built-in pressure sensors and temperature sulfur hexafluoride transformer with output of their state on the graphic display;
- The ability to save the settings of the eight most commonly performed types of testing (insulators, surge protectors, switches, cables, 6.3 kV, 10 kV cables, etc.);
- A choice between manual and automatic operation. The latter involves the installation of the operator values of the test voltage in steps of 0.1 kV, lifting speed of the test voltage, the voltage test current protection operation time of the test;
Parameter | Value |
Supply voltage single-phase AC current, V | 220 ± 22 |
Frequency, Hz | 50 ± 2 |
Highest power consumption, kW, max | 3 |
Highest output voltage, kV: | |
- AC | 50 |
- DC | 70 |
Highest output current, mA: | |
- on an AC voltage | 45 |
- on the DC voltage | 20 |
Relative error voltage, %: | |
- AC voltage from 3 kV to 50 kV |
± 3 |
- DC voltage of 3 kV to 70 kV | ± 3 |
Relative error of current measuring, %: | |
- AC current of 1,0 mA to 45,0 mA | ± 3 |
- DC current of 0,1 mA to 20 mA | ± 3 |
Modes | manual / auto |
Rate of voltage increase, % / s | 1-9 |
Maximum voltage threshold, kV: | |
- on an AC voltage | 52 |
- on the DC voltage | 72 |
Treshold current ofr the power supply, A, max | 10 |
Programmable timer, min, max | 10 |
Archiving of test results, quantity | 32 |
ontrol Unit dimensions, mm, max | 266×240×354 |
ontrol Unit Weight, kg, max | 14 |
BVIEG (HVU-G) dimensions, mm, max | 355×325×350 |
BVIEG (HVU-G) Weight, kg, max | 23 |
KharkovEnergoPribor | |
---|---|
Country/Region: | Ukraine |
Business Nature: | Manufacturer |
Phone: | 7896187 |
Contact: | Oksana (manager) |
Last Online: | 13 Aug, 2015 |