MOTOSOFT SN1*32009 motor soft starter

MOTOSOFT  SN1*32009 motor soft starter
Model:SN1*32009
Brand:ZEROSPAN
Origin:-
Category:Electronics & Electricity / Transducer
Label:ZEROSPAN SN1*32024 , MOTOSOFT SN1*32016 , MOTOSOFT SN1*32009
Price: -
Min. Order:-
Inquire Now
点击这里给我发消息

Product Description

1.SCR overheating protection  
When the heat sink temperature is higher than 80 3 ℃, then the automatic buffer stop or prohibit the start, and a flashing red light Err.1.  
2. To prevent the start due to phase  
If the main power supply due to start phase two flashing red light is Err.1 and ban starts. (Main power K1, K2, K3 can not and then  
Other components, or will be affected less phase detection)  
3. Reversible lock function  
Three-phase power to detect positive and negative phase sequence, can choose to allow or permit the operation of a single direction rotating, and prevent errors reversal  
Damage to equipment. (If the phase sequence error, then Err.1 flashing red light c)  
4. Start Failure  
Start at the constant current mode, when the motor does not start after the completion of 0-120 seconds, then Err.1 red light flashes and four automatic stop.  
5. Motor overload protection  
Overload detection with intelligent, can overload electrical current according to motor size, discriminant trip time and trip time  
(Trip Time) can be adjusted. When the motor overload occurs when the emergency stop (no buffer stop), and a flashing yellow light Err.2.  
6. Motor low load protection  
Motor running current is persistently lower than the set value, the low load protection action, the second flashing yellow light is Err.2, after a period of time the buffer stop.  
(Applied to the water pump load detection, or equipment rotating belt, chain breakage detection .. etc..)  
7. Three-phase current imbalance detection (Unbalance)  
When the three-phase current balance degrees below the set value, Unbalance abnormal movements, the Err.2 three flashing yellow light, the motor buffer stop.  
8. Open or self-sensing circuit fault detection  
After all voltage output when the motor, if the anomaly is detected, then Err.2 and buffer stop flashing yellow light 4.  
9.Thyristor short-circuit detection  
When the boot is produced abnormal current (such as the SCR module short-circuit), then Err.2 five flashing yellow light, and to prohibit start.