1.1 Product Description
Operating Principle:
Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical
signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters,
gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the
signal to other equipment.
Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and
should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items
are damaged or missing, contact SURE.
Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful
to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer
to the nameplate for your customized product’s specification.
3
2. Technical Data
Measuring system
Application range
Liquid: water; diesel; gasoline
(1) Without Impurity
(2) Low viscosity
Measured Value
Primary measured value Flow Rate
Secondary measured value Volume flow
Design
Features
Modular construction The measurement system consists of a flow
sensor and a signal converter. It is available as
compact and as separate version.
Compact version converter N Type: Pulse output without local display
A Type: 4-20mA Output without local display
B Type: Local Display; Lithium Battery Power;
No Output
C Type: Local Display; 24V DC Power; 4-20mA
Output;
Optional Function:
(1) Backup Power Supply: Lithium Battery
(2) Modbus RS485
(3) Pulse Output
Connection Thread: DN4-DN50
Flange: DN15-DN200 (DIN, ANSI, JIS)
Wafer: DN15-DN100
Measurement Ratio Standard – 10:1; Optional: 20:1
Measuring accuracy
Reference conditions Flow conditions similar to EN 29104
Medium: Water
Electrical conductivity: ≥ 300 μS/cm
Temperature: +10...+30°C / +50...+86°F
Inlet section: ≥ 10 DN
Operating pressure: 1 bar / 14.5 psig
Flow Meter Accuracy Standard: 1.0% of rate
Optional: 0.5% of rate
4
Operating conditions
Temperature
Process temperature T1 Level: -20...+80°C
T2 Level: -20...+120°C
T3 Level: -20...+150°C
Ambient temperature
(all versions)
Standard (with aluminum converter housing):
-10…+55°C
Storage temperature -20...+70°
Pressure
EN 1092-1 DN100…DN200: PN 16
DN15…DN80: PN 25
Other pressures on request
ASME B16.5 1/2”...8": 150 lb RF
Other pressures on request
JIS 1/2”...8": 10 K
Other pressures on request
Installation conditions
Installation Take care that flow sensor is always fully filled
For detailed information see chapter "Cautions
for Installation"
Flow direction Forward
Arrow on flow sensor indicates flow direction.