Model: | DC50E |
---|---|
Brand: | ZKSJ |
Origin: | - |
Category: | Industrial Supplies / Machinery / Pumps Vacuum Equipment |
Label: | mini dc pump , dc12v mini pump , ZKSJ DC50E pump |
Price: |
-
|
Min. Order: | - |
DC50E Series
Product Appearance
T sub-series(2phase) S sub-series(3phase) A sub-series(3phase)
Specifications
NO. | Item | Specs |
1 | Dimension and weight | 97.5mmx88.2mmx60.5mm;480g |
2 | External diameter of outlet | 1/2’’ threaded(M20) |
3 | External diameter of inlet | 1/2’’ threaded(M20) |
4 | Driving mechanism | Brushless, magnetic separation |
5 | Material of pump shell | ABS,PES/SPS/PPS/PA66+30%GF (Optional) |
6 | Condition of use | Can continuously work, submersible or land use (not self-priming) |
7 | Suitable medium | Water, oil, or normal acid/ alkaline liquids
(Pre-test needed for special liquid) |
8 | Max working temperature | 60℃(for T sub-series) or 100℃(for S/A sub-series) |
9 | Power consumption | 2.5W~43.2W(for T sub-series) or 2.5W~86.4W(for S/A sub-series) |
10 | Rated voltage | 12Vdc or 24Vdc |
11 | Working voltage range | 5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc |
12 | Max load current | 2.1A (for T sub-series) or 3.8A(for S/A sub-series) |
13 | Max horizontal flow rate | 17L/MIN(for T sub-series) or 20L/MIN(for S/A sub-series) |
14 | Max static lift | 8M(for T sub-series) or 15M(for S/A sub-series) |
15 | Noise class | IP68(suitable for submersible installation) |
16 | Waterproof class | Can be more than 30,000hrs |
17 | Life span | Can be suitable solar panel, batteries, source adapter or other power module |
18 | Power supply | Water protection, dry-run protection, stall protection, stuck protection
(functions are optional for customization) |
19 | Protection function | Speed adjustable by PWM signal, 0~5V analog signal or potentiometer (functions are optional for customization) |
20 | Power regulation function | IP68(suitable for submersible installation) |
Features
Electrical parameters (only for reference,parameters can be customized for specific requirements)
Model No. | Voltage | Max load current | Max flow rate | Max static lift | Power consumption |
V(dc) | A | L/H | M | w | |
DC50E-1250T | 12 | 1.9 | 5.00 | 820 | 22.8 |
DC50E-1250S | |||||
DC50E-1250A | |||||
DC50E-1280S | 12 | 3.6 | 8.00 | 1000 | 43.2 |
DC50E-1280A | |||||
DC50E-2480T | 24 | 1.8 | 8.00 | 1000 | 43.2 |
DC50E-2480S | |||||
DC50E-2480A | |||||
DC50E-24150S | 24 | 3.6 | 15.00 | 1200 | 86.4 |
DC50E-24150A | |||||
NOTE |
|
Difference between 2phase & 3phase brushless DC pump
2phase
(T sub-series) |
|
3phase
(S/A sub-series) |
|
Diagram of 3phase brushless DC pump connection
S-Series A-Series
Potentiometer Speed adjusting connection:
Contact the red and black wire to both ends of potentiometer(variable resistor),then contact the yellow wire to the middle of potentiometer,Speed canbe changed by turning the potentiometer. Potentiometer speed adjusting is the same with VR speed adjusting(Remove the potentiometer and contact the speed adjusting wire like VR speed adjusting connection bellow).
PWM(50-800HZ/Amlitude 5V) or VR(0-5V) Speed adjusting connection:
Contact the yellow wire to the control system's speed control signal output interface(PWM or VR) and contact the black wire to the ground lead in the control system.hang the red wire on the air.
Flow rate-lift Curve
Dimensions of pump
Selection guide
Model | Voltage
(DC) |
Current range | Max lift | Max flow | Inlet Dimension | Outlet Dimension | Speed regulation function | Dry-run / Lock protection |
DC30A | 5~12V | 0.1~0.35A | 3m | 4L/MIN | 8mm | 8mm | customized | Optional |
DC40 | 6~24V | 0.15~1.2A | 8m | 11L/MIN | 14mm | 10mm | PWM/0~5V/manual | Optional |
DC40A | 6~24V | 0.15~1.2A | 6m | 14L/MIN | 14mm | 14mm | PWM/0~5V/manual | Optional |
DC40C | 6~24V | 0.15~1.2A | 6m | 15L/MIN | 1/2’’ thread | 1/2’’ thread | PWM/0~5V/manual | Optional |
DC40F | 6~24V | 0.15~1.2A | 6m | 16L/MIN | 1/2’’ thread | 1/2’’thread | PWM/0~5V/manual | Optional |
DC40H | 6~24V | 0.15~1.2A | 11m | 7.5L/MIN | 11mm | 8mm | PWM/0~5V/manual | Optional |
DC50 | 6~24V | 0.15~3.8A | 7m | 44L/MIN | 22mm | 22mm | PWM/0~5V/manual | Optional |
DC50A | 6~24V | 0.15~3.8A | 5m | 60L/MIN | 27mm | 27mm | PWM/0~5V/manual | Optional |
DC50B | 6~24V | 0.15~3.8A | 13m | 30L/MIN | 22mm | 22mm | PWM/0~5V/manual | Optional |
DC50C | 6~24V | 0.15~3.8A | 6.5m | 42L/MIN | 1/2’’ thread | 1/2’’ thread | PWM/0~5V/manual | Optional |
DC50D | 6~24V | 0.15~3.8A | 6.5m | 42L/MIN | 20mm | 20mm | PWM/0~5V/manual | Optional |
DC50E | 6~24V | 0.15~3.8A | 15m | 25L/MIN | 1/2’’ thread | 1/2’’ thread | PWM/0~5V/manual | Optional |
DC50F | 6~24V | 0.15~3.8A | 15m | 25L/MIN | 1/2’’ thread | 1/2’’ thread | PWM/0~5V/manual | Optional |
DC50G | 6~24V | 0.15~3.8A | 18m | 10L/MIN | 14mm | 8mm | PWM/0~5V/manual | Optional |
DC50K | 6~24V | 0.15~3.8A | 14m | 25L/MIN | 14mm | 14mm | PWM/0~5V/manual | Optional |
DC50W | 24V | 1~3.8A | wave | 28000L/H | Submersible | 58mm | Variable Frequency | Optional |
DC50Q | 24V | 1~3.8A | 5m | 5000 L/H | 1’’ thread | 1’’ thread | Variable Frequency | Optional |
DC60Q | 24v | 1-5A | 5m | 10000L/H | 1.2’’ thread | 1.2’’ thread | Variable Frequency | Optional |
Note:
1, lift and flow rate of product can be customized 2, dimension of inlet/outlet, speed adjusting method and control system can be customized. 3,Food grade and mute pump can be customized. |
Payment Terms: | TT/PAYPAL/WESTERN UNION |
---|---|
shenzhen zhongke century technology Co., Ltd | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 13530547263 |
Contact: | Sundy (sales) |
Last Online: | 15 Aug, 2023 |