Double ended shear beam load cells

Double ended shear beam load cells
Model:QS-S
Brand:Benui Electric
Origin:Made In China
Category:Electronics & Electricity / Electrochemical Products
Label:load cells , truck scale loadcell , weighbridge loadcell
Price: US $46 / pc
Min. Order:50 pc
Inquire Now

Product Description

Description

 

Capacities: (Emax )  
10,20,30,40t Execution standard:
  GB/T 7551-2008 Certificate
Rated output: (eqv OIML R60)
2.0mV/V Combined error: 0.015%
Digital:1,000,000d  
  Sealed to IEC 529:
Accuracy: Protection grade: IP67 or IP68.
C3 OIML R60 Protection against total immersion
  in water for 30 minutes at a pressure
Material of elastomer: corresponding to a 1 m head of water.
Alloy steel or stainless steel  
Dimensions

(In mm. 1mm = 0.03937 inches)

Circuit Diagram
Electrical Termination
4 Core cable standard lengths:
<=30t: 12.0 m, >=40t: 16m
Diameter: Φ6
Connection:
Refer to the following drawing:
Notice:
Do not change the length of cable, or lese,
it will effect the sensitivity of load cell.
Specification

 

 
Item\ Parameter C3 Unit
Rated load (Emax): 10,20,30,40 t
Maximal numbers of load cell verification
Intervals (Nlc):
3000 d
Minimum load cell verification intervals
Intervals ( Vmin):
0.01       % of rated load
Rated output (Cn): 2.0± 0.1% mV/V
*Combined error: 0.015 ±% of rated output
Temperature effect on sensitivity(Tkc): 0.0012  ±% of rated output/°C
Temperature effect on zero balance(Tk0): 0.0008  ±% of rated output/°C
Zero balance: 1.0 ±% of rated output
Input resistance(Rlc): 775±5 Ω(Ohms)
Output resistance(Ro): 702±2 Ω(Ohms)
Insulation resistance: ≥5000 MΩ(Mega-Ohms)
Safe overload: 150 % of rated capability
Ultimate overload: 300   % of rated capability
Operating temperature range: -20~+70/-20~+160 °C / °F
Recommend excitation: 8~15 V( DC or AC)
Maximum excitation: 24 V( DC or AC)
Material of elastomer: Alloy steel / Stainless steel
Protection class: IP67/IP68


    The data for deviation of synthesis error,TK0,TKc are typicl values. The sum of these data meets the
requirements according to OIML R60

Double ended shear beam load cells 1Double ended shear beam load cells 2Double ended shear beam load cells 3Double ended shear beam load cells 4Double ended shear beam load cells 5