BTS-30V10A |
Battery Testing System |
Model: |
BTS- |
30 |
V |
10 |
A |
Material Code: |
CT-4008 |
-30V10A |
- |
NTVA |
- |
P |
Description |
Product Specification |
AC Input |
AC 220V ±10% / 50Hz |
Power |
3413 |
W |
Resolution |
AD: 16bit; DA: 16bit |
Impedence Input |
≥1MΩ |
Voltage |
Measuring Range |
Charge: 150mV~30V |
Dischrge: 150mV~30V |
Discharge Min Voltage |
2.5V |
Accuracy |
± 0.1% of FS |
Stability |
± 0.1% of FS |
Current |
Range |
Charge: 50mA~10A Discharge: 50mA~10A |
Accuracy |
± 0.1% of FS |
Stability |
± 0.1% of FS |
Power |
Output Power Per Channel |
300W |
Stability |
±0.2% of FS |
Time |
Rise Time |
20ms (10%FS~90%FS) |
Step Time |
≤ (365*24) hours/step |
Time Format 00:00:00:000 ( h:min:s:ms ) |
Aux Channel |
Aux Input |
Temperature, Voltage |
Temperature |
﹣25℃~110℃ |
Temperature Accuracy |
±2℃ |
Temperature Resolution |
0.1℃ |
Voltage Range |
10mV~5V |
Voltage Accuracy |
± 0.1% of FS |
Data Accquisition |
Intervals |
Time Interval Δt: (100ms~60000s) |
Voltage Interval ΔU: (60mV~30V) |
Current Interval ΔI: (20mA~10A) |
Frequency |
10Hz |
Charge |
Modes of Operation |
CCC, CVC, CC & CVC, CPC |
End Conditions |
Main Channel: Voltage, Current, Test Time, Capacity |
Aux: Temperature, Voltage |
Discharge |
Modes of Operation |
CCD, CPD, CRD |
End Conditions |
Main Channel: Voltage, Current, Test Time, Capacity |
Aux Channel: Temperature, Voltage |
Pulse |
Charge |
CCC |
Discharge |
CCD |
Minimum Pulse Width |
500ms |
Automated Switch |
Automated switch from charge to discharge for each pulse |
End Condition |
Voltage, Test Time |
Cycle |
Cycles |
Max 65535 |
Steps |
254 |
Nested Fuction |
Max three levels of loops |
Protective Function |
Software |
● Power-off data protection |
● Off-line Operating |
● Main Channels: user-defined safety(upper and lower)tolerance of current, voltage and delay time |
●Aux Channels: User-defined safety (upper and lower) tolerance of temperature and voltage |
Hardware |
Reverse-connecting protection |
Channel Features |
Independent pairs of closed loops for constant current source and constant voltage source |
Channels |
Independent Control |
Detection and Sampling |
4-wire Connecting |
Noise Density |
<85dB |
Data Management |
MYSQL Database |
Communication Means |
TCP/IP Protocol |
Export Formats |
EXCEL2003、2010,TXT,Graph |
Communication Interface |
Ethernet Port |
Number of Channels Per Cabinet |
8 |
Assignable Aux Temperature Per Channel |
Max 248 |
Assignable Aux Voltage Per Channel |
Max 248 |
Operating Environment |
Description |
Product Specification |
Operating Temperature |
0℃~40℃ |
Storage Temperature |
-10℃~50℃ |
Operating Humidity |
≤70% RH |
Storage Humidity |
≤80% RH |
Description |
Product Specification |
Battery Holder |
Universal Holder |
Holder Picture |
|
|
|
|
Universal Holder |
Alligator Holder |
Polymer Holder |
Wiring Terminal |
Picture for reference, please confirm the actual product |
Dimensions (W*D*H)(mm) |
3U(164),480*330*130 |
Equipment Picture |
|
Picture for reference, please confirm the actual product |