Model: | GDJB-PC |
---|---|
Brand: | GOLD |
Origin: | - |
Category: | Electronics & Electricity / Electronic Instrument / Analysis Instrument |
Label: | Tester , Relay Protection Te , Three-Phase Relay P |
Price: |
US $1
/ Set
|
Min. Order: | 1 Set |
I---Introduction
1.GDJB-PC Universal Secondary Injection Relay Test Set is applied to test the relay unit in relay protection system.
2.At the same time GDJB-PC Universal Secondary Injection Relay Test Set could be considered as a universal three phase AC/DC voltage source or current source.
3.It can work alone or connected to computer, inside the relay controller there are new speed digital signal mini PC and real DAC (Digital-to-Analog Converter) template with new high fidelity and high power, the machine has large panel screen and rotating mouse. It is small in volume, high precision.
II---Product Characteristics
1 |
Intelligent mainframe that is used high speed DSP. |
2 |
Separately running |
3 |
Run with connecting to computer |
4 |
16 bit DAC chip |
5 |
Big screen LED |
6 |
“Idiot” operation |
7 |
New type power amplifier |
8 |
Current, voltage output directly |
9 |
Self-protection |
10 |
Abundant contact |
11 |
Compounded structure |
12 |
Abundant capabilities against low price |
II---Functions
1 |
AC current and voltage based protection relay unit test |
2 |
DC current and voltage based protection relay unit test |
3 |
Frequency protection relay unit test |
4 |
Harmonic protection relay unit test |
5 |
Differential protection relay unit test |
6 |
Zero-sequence protection relay unit test |
7 |
Distance protection relay unit test |
8 |
Power system network fault simulation |
IV---Technique Index
1.Max AC current output 30A at per phase limited in 10s, 90A at three phases in parallel limited in 10s, Frequency 20~1000Hz, Continuous current output 10A at per phase , Capacity 420VA at per phase
2. Max DC continuous current output±10 at per phase, maximum voltage 20V, 30A output at three phase in panel
3. Max AC voltage output 120V at per phase, 240V at phase to phase, Frequency 20~1000Hz, capacity 80VA at per phase, 100VA at phase to phase
4.Max DC voltage output±160V at per phase,±320V at phase to phase, capacity 70VA
5.Time counter 0.1ms~9999s, error < 0.1ms
6.AC current and voltage error <0.5%RDG+0.05%FS
7.DC current error<0.5%RDG+0.05%FS, DC voltage error 1%RDG+0.1%FS
8.Binary input: Active node 0~250V, 0~6V for “0”, 6~250V for “1”, passive node: 20mA max
9.Binary output: DC 220V/0.2A, AC 220V/0.5A
10.Power supply:AC220V ± 10%, 50Hz/60Hz
11.Environment temperature: 0~50°C
12.Humidity:≤85%RH
13.Weight:<18KG
V---Technical Parameters
Input |
1-20mA,24V |
Output |
DC:220V/0.2A; AC:220V/0.5A |
Time Measureing |
0.1ms – 9999s |
Power supply |
AC 220V±10%, 50/60Hz |
Ambient temperature |
-10°C - +50°C |
Dimmension&Weight |
Dimmension: 400×300×180mm3; Weight: 20kg
|
Payment Terms: | TT/LC/DP/DA |
---|---|
Chongqing GOLD CLT | |
---|---|
Country/Region: | Chong Qin - China |
Business Nature: | Trading Company |
Phone: | 15683050405 |
Contact: | Jian Lili (Sales) |