Modbus to PROFIBUS PA Gateway

Modbus to PROFIBUS PA Gateway
Model:G0307
Brand:Microcyber
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Meter & Instrument Parts
Label:Profibus PA , PA gateway , Modbus gateway
Price: US $1 / pc
Min. Order:1 pc
Inquire Now

Product Description

Modbus to PROFIBUS PA Gateway G0307

G0307 (original model no. is NCS-MP105) is PROFIBUS /MODBUS protocol gateway, the address of the PROFIBUS-PA slave, MODBUS RTU master. It's a new product of our company and will be put onto the market soon.

  

Product Description

  • G0307 is converter for interfacing Modbus- RTU instruments to a Profibus PA network.
  • Support PROFIBUS DPV1 and PROFIBUS PA 3.01
  • Support AI, AO, DI, DO standard function blocks
  • Support GSD5.0 and standard EDD
  • Support standard DD or EDD specification
  • Electrical interface connected with MODBUS device supports TTL level, RS485 and RS232
  • Able to provide 3.3V or 5V power supply output

  

 

 

NCS-MP105 is a converter device for MODBUS- RTU protocol to PROFIBUS PA protocol. It is able to integrate device/board with MODBUS communication interface to PROFIBUS PA bus system. Bus power supply is selected by NCS-MP105, and NCS-MP105 can provide power supply to the boards the user provides.

 

 

As a MODBUS host, NCS-MP105 communicates with the device with MODBUS-RTU interface, it can achieve read/write operation for MODBUS register data via PA transducer blocks, and convert MODBUS data to PA communication system via PA standard AI,AO,DI,DO function blocks.

 

 

NCS-MP105 Application:

  • Gas detectors
  • Analyzers
  • Positioners
  • Any smart device with MODBUS protocol

 

Physical Parameters

Bus signal: compliant with IEC61158-2 physical layer standard

Bus power supply: 9 ~ 32V

Operating temperature: -40 ~ 85°C

Static current: ≤14mA

Humidity range: 5% ~ 95%,non-dew

Mechanism size: diameter 66mm(can be customized)

 

Supportive MODBUS Communication Parameters

Address: 1 ~ 255

Baud rate: 9600 / 19200 / 15625 / 31250 /62500 / 125000 bps

Data bit: 7 / 8 bits

Calibration: odd / even calibration

Stop bit: 1 / 2 bits

CRC calibration: low byte ahead / high byte ahead

Data format: support various data formats

 

Supportive MODBUS Function Code

Function Code 1: read loop status

Function Code 2: read discrete input status

Function Code 3: read keeping register value

Function Code 4: read input register value

Function Code 6: write loop

Function Code 16:write multiple register values

 

 

Modbus to PROFIBUS PA Gateway 1Modbus to PROFIBUS PA Gateway 2

Member Information

Microcyber Corporation
Country/Region:Liao Ning - China
Business Nature:Manufacturer
Phone:13889336426
Contact:Lisa Liu (sales)
Last Online:12 May, 2016